56-101-01178 Revision K
Page | 88
10.
Step 3 screen is displayed and “IBF Control” button is enabled (see Figure G.7).
Figure G.7 IBF Control Mode Screen
11.
Select “IBF – Control”. The unit will transition into control mode with the Target value
(both ALT & dP) set to the current pressure measure on the Static (Ps) port.
12. Touch ALT or dP zone. A keypad screen is displayed (see Figure G.8). Enter Target
values. Initially, the value will be ALT=0ft and dP=0.0inH
2
O.
Figure G.8
Keypad Screen
13. Wait and allow target suction value to be achieved.
14.
Select “Leak Test”. Monitor dP or ALT values displayed for possible leaks.