16
| E3 IP66 Outdoor Rated User Guide |
Version 1.25
www.bardac.com
P-65 = 1
DI2
=
T3 only
T1
T3
External
User
Switches
VFD Control
Terminals
+24V DC
Drive Switch is disabled
P-65 = 2
DI2
=
T3
AND
Switch REV
T1
T3
External
User
Switches
VFD Control
Terminals
+24V DC
AND
Run Reverse
4.9. Using the Internal Pot (Local Control Versions Only)
On switched drives, the built-in pot (indicated) may be used to directly control the signal level applied to analog input 1, and therefore
the output frequency (motor speed).
To select the built-in pot as the signal source for analog input 1, set P-16 = 8 In-pot.
4.10. Control Terminal Connections
2 (Dl 1)
1 (+24V DC/ 100mA)
5 (+10V DC/ 10mA)
6 (AI 1/ DI 4*)
(AO / DO*) 8
(0V/ COM) 9
AO mode:
0-10V
DO mode:
24V DC
0-10 V
0/4-20 mA
20-4 mA
0-10 V
10-0 V
0/4-20 mA
20-4 mA
10 (RL-COM)
11 (RL-NO)
NOTE
* Dashed lines shows connection for analog inputs and output in digital mode
7 (0V/ COM)
3 (Dl 2)
4 (AI 2/ Dl 3*)
Key
Default Function
Sec.
Page
Open
Closed
1
+24V DC
24 Volt DC Output
On-board +24V DC Supply (100mA)
2
DI 1
Digital Input 1 (Run Enable)
STOP
RUN
3
DI 2
Digital Input 2
FORWARD
REVERSE
4
AI 2 / DI 3 Analog Input 2 / Digital Input 3
AI1 Reference
Preset Speed 1 (P-20)
Power & Contr
ol Wiring
4