7960-464C
Page
10 of 11
WRAP DRAIN TUBE AROUND
MANIFOLD SUPPORT BRACKET
LEAVING THE TUBING LOOSE
ENOUGH TO AVOID KINKING
REMOVE KNOCKOUT, INSTALL
SNAP BUSHINGS, AND ROUTE TUBE
IN BASE
THROUGH HOLE
ROUTE TUBE
ATTACH DRAIN TUBE
TO TRANSITION
MIS-2335
(Used for WG42, WG48, WG60 & all WF models only.)
INSTALLING DRAIN TUBING
To install the silicone drain tubing, refer to
Figure 5 and remove the two knockouts shown.
Install the two snap bushings (included) into the
7/8" holes. Attach one end of the drain tubing to
the drain tee fitting and secure with the hose
clamp included. Route the drain tubing as shown
in Figure 5 as to form a "trap" in the line. Make
sure that the tubing is run through all four holes so
it exits the lower unit base.
NOTE: Do not use any other type of material for
the purpose of draining this vent system.
Doing so could result in damage to the
unit.
Once the drain tubing is installed, install the
"Silicone Fill Plate Gasket" and "Unit Fill Plate" as
shown in Figure 6. Follow installation procedure
exactly – as this is a critical water seal.
FIGURE 5
INSTALLING DRAIN TUBING
Summary of Contents for VVK-5A
Page 4: ...7960 464C Page 4 of 11 FIGURE 2 VERTICAL VENTING INSTALLATION FOR WG24 WG30 WG36 MODELS ...
Page 5: ...7960 464C Page 5 of 11 FIGURE 2A VERTICAL VENTING INSTALLATION FOR WG42 WG48 WG60 MODELS ...
Page 6: ...7960 464C Page 6 of 11 FIGURE 2B VERTICAL VENTING INSTALLATION FOR ALL WF MODELS ...