1.2 Safety training to be provided by the installer
Users definition
The UDX projector is intended for persons who have been instructed and trained by a skilled person (installer
or service personnel) to identify energy sources that may cause injury and to take precautions to avoid
unintentional contact with or exposure to those energy sources.
The skilled person must instruct the user about:
•
High intensity light beam. The user must respect the exclusion zone, based on the light beam Hazard
Distance (HD).
•
Dangerous energy sources inside the projector. The user is not allowed to remove any cover from the
projector.
•
The installation, maintenance or service is for skilled persons only.
•
The requirements for a
restricted access location, an exclusion zone
and a
restriction zone
.
Restricted access location
To protect untrained persons and children, the projector must be installed in a
restricted access location
.
The definition of a
restricted access location
is a location for equipment where both of the following
paragraphs apply:
•
Access can only be gained by skilled persons (installer or service personnel) or persons who have been
instructed and trained by a skilled person. The persons must have been instructed about the reasons for
the restriction applied to the location and about the precautions that shall be taken.
•
Access is only possible through the use of the tool or lock and key, or other means of security, and is
controlled by the authority responsible for the location.
Why a restricted access location: this is an RG3 product. Based on international requirements, no person is
allowed to enter the projected beam within the zone between the projection lens and the related Hazard
Distance (HD). This shall be physically impossible by creating sufficient separation height and width or by
placing optional barriers. Within the restricted area operator training is considered sufficient. The applicable
separation heights and widths are discussed in
High Brightness precautions: Hazard Distance
”
, page 16.
Exclusion zone
The projector radiates heat on its external surfaces and from ventilation ducts during normal operation.
Exposing flammable or combustible materials into close proximity of this projector could result in the
spontaneous ignition of that material, resulting in a fire. For this reason, it is absolutely necessary to leave an
exclusion zone around all external surfaces of the projector whereby no flammable or combustible materials
are present:
•
The exclusion zone must not be less than 40 cm (16 in).
Restriction zone
To protect untrained users and children against high intensity light beams, the light beam Hazard Distance
(HD) shall be taken into account.
Summary of Contents for UDX Series
Page 1: ...ENABLING BRIGHT OUTCOMES Installation manual UDX...
Page 4: ......
Page 28: ...R5906113 09 UDX 28 Installation process...
Page 50: ...R5906113 09 UDX 50 Image 4 11 Installation procedures...
Page 60: ...R5906113 09 UDX 60 Installation procedures...
Page 72: ...R5906113 09 UDX 72 Flight case and rigging frame...
Page 78: ...R5906113 09 UDX 78 Pulse SFP input use cases...
Page 88: ...R5906113 09 UDX 88 Projector covers...
Page 94: ...Glossary R5906113 09 UDX 94...
Page 98: ...Index R5906113 09 UDX 98...