R5906788-03
Thor series
100
About Default settings
The restore of factory setting is a feature that allows removing all settings performed on the ICMP and
replaces them with the default values set at the factory. Please refer to the Communicator user guide for
further information.
About the ICMP internal clock
The crystal on the ICMP board that manages the clock shows a certain drift (all crystals do). With the
Communicator the internal clock can be adjusted. This maintenance action should be repeated every 3
months. When neglected the system will locks up.
From ICMP software version 1.2.1 onwards it is possible to enable NTP (Network Time Protocol). You have to
configure (at installation) an IP address where the ICMP can find a sync signal. From then on, and as long as
the connection is active, the ICMP will automatically keep its clock correct. For detailed instructions see user
guide of the Communicator.
9.13 ICMP reset
This procedure requires that ICMP version 1.2.4 or later is installed.
ICMP reset possibilities
•
The Star button on the local keypad (Not for C- and B-series)
•
The ICMP reset button in the GUI of the Communicator.
•
The ICMP reset button in the GUI of the Commander.
•
The ICMP reset button in the GUI of the Web Commander.
•
The ICMP hardware reset button located on the front panel of the ICMP (Not recommended, use only
when all other reset possibilities are exhausted!)
How to reset the ICMP?
1.
Click on the ICMP
reset button
in the GUI of the
Web Commander
or
Click on the ICMP
reset button
in the GUI of the
Commander
Note:
It can be that the Commander or WEB-Commander is not able to send the reset command.
or
click on the ICMP
reset button
in the GUI of the
Communicator
(recommended)
or
press the
Star button
on the
local keypad
for a few seconds (Not for C- and B-series)
As a result the projector is safely prepared for the ICMP reboot. All ongoing events on the ICMP (e.g. ingest)
are requested to end. After a few seconds the ICMP is requested to restart. The READY LED on the front
panel of the ICMP starts to blink orange.
In case the ICMP is installed in DP4K-L series projector the lasers are switched off and the projector remains
in the same mode (e.g. Conditioned). The Star button on the local keypad starts blinking green. After the reset
of the ICMP the lasers are switched on again.
Once the READY LED lit continuous green the ICMP is up and running.
2.
Did the reset of the ICMP fail?
►
If yes,
perform a hardware reset as follows:
1.
switch off the lasers of the projector or switch of the projector lamp.
2.
press the ICMP
hardware reset button
a few seconds (reference 3 Image 9-13) .
Warning:
Resetting the ICMP with the hardware reset button may cause damage to the content on the
HDDs. A re-configuration of the whole system may be required!
Summary of Contents for Thor Series
Page 1: ...ENABLING BRIGHT OUTCOMES Installation manual Thor series...
Page 2: ...Barco NV President Kennedypark 35 8500 Kortrijk Belgium www barco com en support www barco com...
Page 8: ...R5906788 03 Thor series 8...
Page 24: ...R5906788 03 Thor series 24 Safety Information...
Page 26: ...R5906788 03 Thor series 26 Commander Web Commander System overview...
Page 44: ...R5906788 03 Thor series 44 Installation process...
Page 68: ...R5906788 03 Thor series 68 Lenses Lens selection...
Page 78: ...R5906788 03 Thor series 78 Installing a HDD into the ICMP ICMP...
Page 110: ...R5906788 03 Thor series 110 Starting up...
Page 122: ...R5906788 03 Thor series 122 Scheimpflug...
Page 130: ...R5906788 03 Thor series 130 Convergence...
Page 142: ...R5906788 03 Thor series 142 Preventative maintenance actions...
Page 160: ...R5906788 03 Thor series 160 Specifications...
Page 168: ...R5906788 03 Thor series 168 Pin configurations...
Page 172: ...R5906788 03 Thor series 172 Environmental information...
Page 176: ...Glossary R5906788 03 Thor series 176...
Page 181: ...R5906788 03 Thor series 181...
Page 182: ...Barco NV President Kennedypark 35 8500 Kortrijk Belgium www barco com R5906788 03 07 09 2018...