7. Servicing
7.3
Install the re-sync unit
C
AUTION
:
Ensure to perform this procedure in a dry and clean environment with a low humidity level. A high
humidity level inside a sealed tile will damage the internal fans and other electronic parts. Place, if necessary,
some small bags with a liquid absorbing substance (silica gel) inside the tile to absorb the remaining humidity.
C
AUTION
:
Always replace the old sealing ring of the re-sync unit with a new one for each time the re-sync
unit is removed. This to ensure a good sealing between the SLite tile and the re-sync unit. To forsake this
instruction will result in internal damage of the SLite tile.
Necessary tools
10 mm nut driver
Necessary parts
•
New sealing ring (R724571).
•
Four bolts M6 x 16.
How to install the re-sync unit of an SLite tile ?
1. Place a new sealing ring (O) on the re-sync unit.
Tip:
Use the four bolts (M6 x 16) to keep the sealing ring on its place.
2. Reconnect the internal power cable (P) and data cable (D) with the re-sync unit.
D
O
P
Image 7-3
3. Gently place the re-sync unit into position.
4. Fasten the re-sync unit with four bolts M6 x 16, using a 10 mm nut driver.
38
R5976575 FIXED SLITE DISPLAY 08/03/2006
Summary of Contents for SLite 10
Page 1: ...Fixed SLite display Installation Manual R5976575 04 08 03 2006 ...
Page 4: ......
Page 6: ...Table of contents 2 R5976575 FIXED SLITE DISPLAY 08 03 2006 ...
Page 16: ...2 Installation requirements 12 R5976575 FIXED SLITE DISPLAY 08 03 2006 ...
Page 24: ...3 Components of a fixed SLite display 20 R5976575 FIXED SLITE DISPLAY 08 03 2006 ...
Page 44: ...7 Servicing Image 7 5 40 R5976575 FIXED SLITE DISPLAY 08 03 2006 ...
Page 48: ...7 Servicing 44 R5976575 FIXED SLITE DISPLAY 08 03 2006 ...
Page 54: ...A Specifications 50 R5976575 FIXED SLITE DISPLAY 08 03 2006 ...
Page 55: ...B Order info B ORDER INFO Overview Order info R5976575 FIXED SLITE DISPLAY 08 03 2006 51 ...