7. Advanced
Image 7-104
7.5.2
Lamp runtime warning
What can be done ?
When the lamp has reached a predetermined runtime , a warning message will be displayed on the screen. The lamp runtime
warning can be set in a range from 30 to 200 hours. The runtime warning is displayed by default at 30 hours before end of lamp
lifetime.
How to set the lamp runtime warning ?
1. Press
MENU
to activate the Tool bar
2. Press
→
to select the
Lamp
item
3. Press
↓
to Pull down the
Lamp
menu
4. Use
↑
or
↓
to select
Runtime warning...
Image 7-105
5. Press
ENTER
A dialog box is displayed
Image 7-106
6. Use
←
or
→
, the numeric keys on the remote, or the keypad to change the runtime warning setting.
7.5.3
Lamp mode
What are the different lamp modes ?
Single mode
The projector will always switch to the lamp with the shortest runtime when the difference between the runtimes of lamp1 and lamp
2 reaches
100 hours
, switching from one lamp to another happens only at switching on of the projector and not during operation.
When the lamp fails or reaches its maximum runtime the projector switches automatically to the other lamp without interrupting the
projection.The failure is logged and the lamp will never be initialized in the future.
98
R59770247 SIM 5H 04/06/2008
Summary of Contents for SIM 5H
Page 1: ...Sim 5H Owner Manual R9040390 R59770247 00 04 06 2008...
Page 4: ......
Page 8: ...Table of contents 4 R59770247 SIM 5H 04 06 2008...
Page 10: ...1 Safety Instructions 6 R59770247 SIM 5H 04 06 2008...
Page 18: ...3 Installation guidelines 14 R59770247 SIM 5H 04 06 2008...
Page 48: ...6 Getting started 44 R59770247 SIM 5H 04 06 2008...
Page 79: ...7 Advanced Image 7 59 Image 7 60 Image 7 61 R59770247 SIM 5H 04 06 2008 75...
Page 166: ...7 Advanced 162 R59770247 SIM 5H 04 06 2008...
Page 170: ...Index 166 R59770247 SIM 5H 04 06 2008...
Page 172: ...List of tables 168 R59770247 SIM 5H 04 06 2008...