3. Advanced Commands
Receive (acknowledge)
Start
\xfe
Projector address
\x01
Command[0]
\x00
Command[1]
\x06
Checksum
\x07
Stop
\xff
Receive (Awnser)
Start
\xfe
Projector address
\x01
Command[0]
\x21
Command[1]
\x86
Data [0]
\x10
Data [1]
\x00
Checksum
\xb8
Stop
\xff
3.18 AutoImage setup, Write
Description
Sets up the AutoImage i.e. selects the AutoImage parameters.
Command
Command [0]
\x20
Command [1]
\x90
Data
Unsigned word.see chapter "1. Serial communications Basics", "Data words", page 6
Data[0] = unsigned byte (msb)
Data[1] = unsigned byte (lsb)
Parameter
Data[0]
Data[1]
Hex Value
Total Pixels
0000
0001
\x01
Contrast/Brightness
0000
0010
\x02
Phase
0000
0100
\x04
Start pixel/line
0000
1000
\x08
Total cont/bright
0000
0011
\x03
...
Example
Set up AutoImage for “Total Pixels”
132