background image

M

EDIA

F

IXED

SL

ITE

D

ISPLAY

I

NSTALLATION

M

ANUAL

17102003

R5976575/02

Summary of Contents for R9004200

Page 1: ...MEDIA FIXED SLITE DISPLAY INSTALLATION MANUAL 17102003 R5976575 02 ...

Page 2: ...Barco nv Media Noordlaan 5 8520 Kuurne Phone 32 56 36 89 70 Fax 32 56 36 88 24 E mail media barco com Visit us at the web www barco com Printed in Belgium ...

Page 3: ...e claims of the purchaser will be rendered invalid Not included in the guarantee coverage are system failures which are attributed to programs or special electronic circuitry provided by the purchaser e g interfaces Normal wear as well as normal maintenance are not subject to the guarantee provided by Barco either The environmental conditions as well as the servicing and maintenance regulations sp...

Page 4: ......

Page 5: ...les 15 2 5 2 Data cables 17 2 6 Digitizer 18 2 7 Control Software 18 3 Physical installation 19 3 1 Installation of the Support Structure 19 3 2 Mounting the SLite tile 20 3 3 Cabling of the SLite display 24 3 3 1 SLite tile input output ports 24 3 3 2 Power cabling 25 3 3 2 1 Connections with a Mono Phase Power Box 25 3 3 2 2 Connections with a Custom Power Box 27 3 3 3 Data cabling 28 4 Servicin...

Page 6: ...Table of contents 2 R5976575 FIXED SLITE DISPLAY 17102003 ...

Page 7: ...turing processes in order to achieve part strength Consult BARCO for assistance with custom applications Always follow BARCO Installation Instructions Contact BARCO if you should have any question regarding the safety of an appli cation The manufacturer assumes no liability for incorrect inadequate irresponsible or unsafe assembly of systems Product Care Structural Mounting Components should be ke...

Page 8: ...ments accessories specified by the manufacturer Disconnect the power to this apparatus during lightning storms or provide suitable additional lightning protection Unplug this apparatus when unused for long period of time Refer all servicing to qualified service technicians personnel Servicing is required when the apparatus has been damaged in any way such as power supply cord or plug is damaged th...

Page 9: ...alled near the equipment and be easily accessible or a readily accessible general disconnect device shall be incorporated in the fixed wiring This equipment MUST be earthed In order to protect against risk of electric shock the installation should be properly grounded Defeating the purpose of the grounding type plug will expose you to the risk of electric shock Power system It is recommended to us...

Page 10: ...1 Safety 6 R5976575 FIXED SLITE DISPLAY 17102003 ...

Page 11: ...eral demands regarding strength wind load cooling humidity accessibility etc and also comply with the local regulations regarding such installations The support struc ture must be accessible from the rear and be provided with attachment points to attach the SLite tiles Those attachment points exist in perfectly aligned precision plates which simplifies SLite tile mounting Screen supporting securin...

Page 12: ... an individual basis Never construct a wall if there is uncertainty regarding the stability of an installation or the load holding capabilities If there are doubts on a system s viability consult Barco for advise on professional rigging organizations Example of a support structure Image 2 2 The support structure in the above example is pure illustrative for a H7 x V5 SLite display Several variants...

Page 13: ...mate in picture quality The SLite is an IP65 rating rugged module and can be hot swapped which enables service of a display panel and its components while the rest of the display continues playing Image 2 3 Order info SLite tiles Article No Description R9004200 SLite10 R9004300 SLite14 Specification SLite10 tile Name Value Brightness 6 500 NIT Calibrated brightness 5 000 10 NIT Visual resolution 9...

Page 14: ...al resolution 14 mm Physical resolution 28 mm Horizontal viewing angle 120 º Vertical viewing angle 60 º Lifetime half brightness 50 000 h Power consumption panel Max 720 Avg 150 W Weight panel 34 kg Processing 14 bit Colors 4 400 billion Refresh rate 800 Hz minimum Contrast ratio 1000 1 Ruggedness IP65 only if all connection ports are used correctly with Barco s outdoor cables or dummy plugs for ...

Page 15: ...s there is a range of adapted Custom Power Boxes 2 4 1 Standard Mono Phase Power Box Introduction The small design of the Standard Mono Phase Power Box makes this power box suitable for applications installed in narrow places This power box contains 5 secured circuits of 16A 230V Each circuit is provided with an output cable which can be connected with the power linking cable of the first SLite ti...

Page 16: ...R PLUG E Standard Mono Phase Power Box A Image 2 5 Standard Mono Phase Power Box in a SLite configuration A Standard Mono Phase Power Box B Output cable C Power linking cable D SLite tile E Dummy power plug Order info Article No Description Image R9850058 Standard Mono Phase Power Box outdoor image 2 6 Image 2 6 12 R5976575 FIXED SLITE DISPLAY 17102003 ...

Page 17: ... up to ten These special outputs are not suitable for direct connection with the tiles but one output can be split up into six outputs by using a Spider Connector Each output of a Spider Connector can provide a series of maximum three SLite tiles So one adapted power box with ten special outputs can maximum provide 10 x 6 x 3 180 SLite tiles For SLite Displays larger then 180 tiles several custom ...

Page 18: ... phase 230V 4 outputs 72 R9851243 Custom Power Box 3 phase 230V 5 outputs 90 R9851244 Custom Power Box 3 phase 230V 6 outputs 108 R9851245 Custom Power Box 3 phase 230V 7 outputs 126 R9851246 Custom Power Box 3 phase 230V 8 outputs 144 R9851247 Custom Power Box 3 phase 230V 9 outputs 162 R9851248 Custom Power Box 3 phase 230V 10 outputs 180 R9851250 Custom Power Box 3 phase 380V 2 outputs 36 R9851...

Page 19: ...e image 2 11 R9850260 Waterproof power source cable C20 waterproof C19 waterproof 9 meter Used to distribute power from SLite tile to AEC or between Fiberlink Receiver and SLite tile image 2 12 R9851260 Multi power cable of 10 meter Used to distribute power between Custom Power Box and Spider connector R9851261 Multi power cable of 20 meter Used to distribute power between Custom Power Box and Spi...

Page 20: ...output cable image 2 14 and image 2 15 R9851662 Waterproof Spider connector with 6 power outputs C19 with custom lengths Spider support bracket included Used to distribute power from a multi power cable to the SLite tiles Maximum 3 SLite tiles per Spider output cable R9850280 Package with five dummy power plugs image 2 17 Image 2 9 Image 2 10 Image 2 11 Image 2 12 Image 2 13 Image 2 14 Image 2 15 ...

Page 21: ...ta from SLite tile to AEC or from Fiberlink Receiver to SLite tile image 2 19 R9851216 DVI MDR waterproof IN data cable of 5 meter Used to link data from D320 Digitizer to SLite tile image 2 20 R9851218 DVI MDR data cable of 5 meter Used to link data from D320 Digitizer to Fiberlink Transmitter image 2 21 R9851219 DVI MDR data cable of 1 meter Used to link data from D320 Digitizer to Fiberlink Tra...

Page 22: ... with the Digitizer and Display this can be used when connected to the Digitizer through a serial RS232 connection Refer to the Manual of the Digitizer for more information about the Digitizer 2 7 Control Software General The Control Software is designed as a graphic user interface GUI and can be used to control and configure the Digitizer as well as the Barco LED Wall via a PC e g XLite Toolset R...

Page 23: ...fessional rigging organizations Calibration tools for the SLite mounting plates BARCO provides mounting plates for the SLite tiles which has to be attached to the support structure To align the mounting plates correctly the use of calibration tools is recommended BARCO provides two different calibration tools One to align the mounting plates in a vertical direction and one to align in a horizontal...

Page 24: ...ted into the assembled and installed support structure Image 3 3 The following procedure must be performed by minimum three authorized and qualified technical persons which are thoroughly familiar with the product and all of the proper safety checks of this product To do otherwise increases the risk of hazard and injury to the user 20 R5976575 FIXED SLITE DISPLAY 17102003 ...

Page 25: ... persons are required at the front of the LED display to perform this action Both hands must be free to insert a tile in a LED wall Therefore the use of a ladder to insert a tile is forbidden Only a solid scaffold or a Z lift is allowed Tip You can use the eye bolts on the top side to lift the SLite tile using a crane to the desired height 4 Place a prevailing torque type hexagon flange nut on eac...

Page 26: ...3 Physical installation Image 3 5 Image 3 6 22 R5976575 FIXED SLITE DISPLAY 17102003 ...

Page 27: ...ing slot Image 3 8 Place the SLite tiles beside one another from the middle of the row to the sides Image 3 9 Build the SLite Display row by row from bottom to top Image 3 10 Start mounting the next row Image 3 11 Place the SLite tiles beside one another from the middle of the row to the sides Image 3 12 Complete SLite Display R5976575 FIXED SLITE DISPLAY 17102003 23 ...

Page 28: ...nector is used to loop the data through The power ports consist in one waterproof C19 connector in the lower left corner and one waterproof C20 connector in the upper left corner of the connection module respectively used for power input and power output B C A D E Image 3 13 SLite input output ports A Connection module B Power input port C Power output port D Data input port E Data output port A I...

Page 29: ...e lowest tile in a column of maximum three 4 Complete each power branch by connecting a maximum of three tiles with power linking cables to each other in a daisy chain manner Warning Maximum 3 three tiles per branch are allowed Connecting more then three tiles with one output cable will overload the circuit 5 Terminate the power output socket of the last tile in each column with a Dummy Power Plug...

Page 30: ...ple of power cabling with a Mono Phase Power Box SLite Display Rear View A POWER DATA OUT IN AEC F Power linking cable D Power Box B Power output cable C Dummy power plug E POWER DATA OUT IN POWER DATA OUT IN POWER DATA OUT IN POWER DATA OUT IN POWER DATA OUT IN POWER DATA OUT IN POWER DATA OUT IN POWER DATA OUT IN POWER DATA OUT IN POWER DATA OUT IN POWER DATA OUT IN POWER DATA OUT IN POWER DATA ...

Page 31: ...ack colored ring for power red for data image 3 21 5 Start creating power branches by connecting the output cables of the Spider connector with the power input socket of the lowest tile in a column of maximum three 6 Complete each power branch by connecting a maximum of three tiles with power linking cables to each other in a daisy chain manner Warning Maximum 3 three tiles per branch are allowed ...

Page 32: ...r linking cable Image 3 20 Spider support bracket Image 3 21 Sealing rings A Red sealing ring for DATA IN and DATA OUT sockets B361595 B Black sealing ring for POWER IN and POWER OUT sockets B361243 Image 3 22 Dummy Power Plug 3 3 3 Data cabling What has to be done Connecting tiles to one another and then to the Digitizer There are two data connection ports on the back of each tile the DATA IN and...

Page 33: ...t This daisy chain linking can be performed either in the horizontal or vertical directions starting in a corner of the SLite display 4 Place a Dummy Data plug on the Data OUT connector of the last tile in the chain image 3 24 5 Make sure that all plug holder clamps are locked firmly 6 Specify in the setup Controlling Software how the data linking of the tiles is realized Horizontal or Vertically ...

Page 34: ... 3 25 A Client B Network C SLite display rear view D AEC E Data cables are daisy chained to all tiles F First tile may be in any corner G Last tile will be in a corner It s recommended that the data cable interconnection got a direction at right angles to the power cable inter connection because the re synchronizer of the previous tile is able to power up the data connection for the next 2 tiles S...

Page 35: ... BARCO parts are allowed 4 2 Removing a SLite tile What has to be done Removing an installed SLite tile from the LED wall in a secure manner This can only be done via back and front access at the same time At least three qualified persons are required to get the job done Two persons at the front and one at the rear of the LED wall The following procedure must be performed by minimum three authoriz...

Page 36: ...ockets are sealed up using a power and data linking cable 6 The person at the rear of the LED wall grabs the SLite tile by the rear handles and pushes the tile gently a little bit forward out of the LED wall Simultaneous the two persons in front of the LED wall grab the outgoing tile at the bottom and by the side handles image 4 7 image 4 8 7 Remove the safety cable image 4 9 image 4 10 Tip The ey...

Page 37: ...4 Servicing Image 4 9 Image 4 10 R5976575 FIXED SLITE DISPLAY 17102003 33 ...

Page 38: ...4 Servicing 34 R5976575 FIXED SLITE DISPLAY 17102003 ...

Page 39: ... and data linking cable Make sure that all plug holder clamps are locked firmly 2 Place the tile flat on a solid table with the LED s facing upwards and vaporize through different directions the window cleaning product on the shaders and LED s Caution Do not use industrial grease removers Use only materials or chemicals that are inert nonabrasive noncorrosive and non marking 3 Brush down all dirt ...

Page 40: ...5 Maintenance 36 R5976575 FIXED SLITE DISPLAY 17102003 ...

Page 41: ...ns 25 27 Custom Power Box 27 Mono Phase Power Box 25 Power Box 11 13 Custom 13 Mono Phase 11 Power Boxes 11 Power cables 15 R Remove 31 SLite tile 31 S Safety 3 4 Guidelines 3 Important Instructions 4 Warnings 4 Servicing 31 35 Cleaning 35 Safety 31 SLite 19 Physical installation 19 SLite tile 20 Mounting 20 SLite tiles 9 Support structure 7 Support Structure 19 Installation 19 System 7 9 11 Intro...