R5906897 /02
Prometheus III
22
2.1 Installation requirements
Environmental conditions
The table below summarizes the physical environment in which the Prometheus III may be safely operated or
stored.
Environment
Operating
Non-Operating
Ambient Temperature
10°C (50°F) to 35°C (95°F)
-15°C (5°F) to 60°C (140°F)
Air cleanliness
Clean office environment (equivalent with
cleanroom standard ISO 14644-1 ISO Class
9)
n.a.
Humidity
5% to 85% RH Non-condensed
5% to 95% RH Non-Condensed
Altitude
-60 (-197Ft) to 3000m (9843Ft)
-60 (-197Ft) to 10000m (32810Ft)
Let the projector acclimatize after unpacking. Neglecting this may result in a startup failure of the
Light Processor Unit.
Use in high altitude conditions
When 3000 m environmental condition is combined with the highest permissible temperature (35°C ambient),
the projector may be expected to go into warning status. Hence, for high altitude conditions, we advise max
30°C ambient condition (25°C is preferred).
Furthermore, to avoid temperature warnings on laser banks, we advise in high altitude to set cooler fans to
100%.
Cooling requirements
For functionality and reliability, the Prometheus III requires accurate temperature control and cooling.
Therefore a liquid cooling system is provided consisting of liquid circuits inside the Prometheus III which are
connected via hoses to external coolers. Only coolers and hoses exclusively developed for this application
and approved by Barco are allowed to be used.
Main Power requirements
The Prometheus III operates from a nominal single phase power net with a separate earth ground PE.
Projector
Power requirements
Prometheus III
200-240 VAC, 50-60Hz, 20A at 200 VAC
The power cord required to connect the projector with the power net is not delivered with the projector. It is the
responsibility of the customer to provide the correct type of power cord. The cross-sectional area of the
conductors in the power supply cord shall not be less than 4 mm² or 10 AWG, minimum 300V.
To protect operating personnel, the National Electrical Manufacturers Association (NEMA) recommends that
the instrument panel and cabinet be grounded. In no event shall this projector be operated without an
adequate cabinet ground connection.
The AC supply must be installed by a qualified electrician in conformance to local codes. Hardware, wire sizes
and conduit types must comply with local codes.
A readily accessible disconnect device shall be incorporated externally to the equipment for removal of the
power to the equipment mains terminals.
The building installation must be provided with a circuit breaker of max. 40A to protect the complete unit.
Exhaust outlet for external fan
The exhaust outlet has an output voltage of 200
–
240V at 50
–
60 Hz; switched and maximum 3 amperes is
allowed.
Summary of Contents for Prometheus III
Page 1: ...ENABLING BRIGHT OUTCOMES Installation manual Prometheus III...
Page 8: ...R5906897 02 Prometheus III 8...
Page 32: ...R5906897 02 Prometheus III 32 Installation process...
Page 62: ...R5906897 02 Prometheus III 62 Physical installation stand alone cooler...
Page 80: ...R5906897 02 Prometheus III 80 Lenses lens holder...
Page 98: ...R5906897 02 Prometheus III 98 Input communication...
Page 100: ...R5906897 02 Prometheus III 100 Installing a HDD into the ICMP ICMP...
Page 132: ...R5906897 02 Prometheus III 132 Communicator Touch Panel...
Page 148: ...R5906897 02 Prometheus III 148 Removal and installation of the projector covers...
Page 152: ...R5906897 02 Prometheus III 152 Preventative maintenance actions...
Page 170: ...R5906897 02 Prometheus III 170 Convergence...
Page 176: ...R5906897 02 Prometheus III 176 Color calibration...
Page 199: ...R5906897 02 Prometheus III 199 Environmental Information...