![Barco Prometheus III Installation Manual Download Page 118](http://html1.mh-extra.com/html/barco/prometheus-iii/prometheus-iii_installation-manual_4205234118.webp)
R5906897 /02
Prometheus III
118
8.10 ICMP HDD status LEDs
ICMP HDD status LEDs
5
4
Image 8-11
4
HDD I/O LED
5
RAID LED
Status overview HDD I/Oand RAID LEDs:
HDD I/O
RAID
ICMP HDD Status
Off
Off
HDD idle / Disk in RAID OK.
Blinking Green
Off
HDD I/O activity / Disk in RAID OK.
Blinking Green
Blinking Red
HDD I/O activity / RAID rebuilding.
Off
Red
HDD idle / Disk error. See troubleshooting table below for curative actions.
Troubleshooting
Situation
Solution
One disk failed (red LED) +
RAID degraded
.
The ongoing event is not interrupted.
Note:
The disk status (RAID degraded) can be
retrieved via the (Web) Commander. See user guide
of the (Web) Commander.
1.
Switch off the power.
2.
Replace the defect HDD with approved model of
the same storage capacity. See procedure
“
and
“
Installing a HDD into the ICMP
”
Ensure to insert the HDD firmly.
3.
Switch on the power.
Result:
As soon the new HDD is detected by the
ICMP the rebuild of the RAID is started (Blinking red
LED).
One disk failed (red LED) + Error 10580
“
local
storage not available
”
.
Note:
The disk status (Error code) can be retrieved
via the (Web) Commander. See user guide of the
(Web) Commander.
1.
Switch off the power.
2.
Replace the defect HDD with approved model of
the same storage capacity. See procedure
“
and
“
Installing a HDD into the ICMP
”
Ensure to insert the HDD firmly.
3.
Switch on the power.
Result:
As soon the new HDD is detected by the
ICMP the rebuild of the RAID is started (Blinking red
LED).
Summary of Contents for Prometheus III
Page 1: ...ENABLING BRIGHT OUTCOMES Installation manual Prometheus III...
Page 8: ...R5906897 02 Prometheus III 8...
Page 32: ...R5906897 02 Prometheus III 32 Installation process...
Page 62: ...R5906897 02 Prometheus III 62 Physical installation stand alone cooler...
Page 80: ...R5906897 02 Prometheus III 80 Lenses lens holder...
Page 98: ...R5906897 02 Prometheus III 98 Input communication...
Page 100: ...R5906897 02 Prometheus III 100 Installing a HDD into the ICMP ICMP...
Page 132: ...R5906897 02 Prometheus III 132 Communicator Touch Panel...
Page 148: ...R5906897 02 Prometheus III 148 Removal and installation of the projector covers...
Page 152: ...R5906897 02 Prometheus III 152 Preventative maintenance actions...
Page 170: ...R5906897 02 Prometheus III 170 Convergence...
Page 176: ...R5906897 02 Prometheus III 176 Color calibration...
Page 199: ...R5906897 02 Prometheus III 199 Environmental Information...