background image

MDRC-1219

User Guide

19” 1MP (Multi-Touch) Color LCD Display

MDRC-1219 - MDRC-1219 TS

MDRC-1219 HB - MDRC-1219 HB TS

K5902137 (451920612603)/02
23/02/2018

Summary of Contents for MDRC-1219 HB

Page 1: ...MDRC 1219 User Guide 19 1MP Multi Touch Color LCD Display MDRC 1219 MDRC 1219 TS MDRC 1219 HB MDRC 1219 HB TS K5902137 451920612603 02 23 02 2018...

Page 2: ...26 22 62 Support www barco com en support Visit us at the web www barco com Registered address Barco NV President Kennedypark 35 8500 Kortrijk Belgium Phone 32 56 23 32 11 Fax 32 56 26 22 62 Support w...

Page 3: ...t 15 3 8 sRGB color space 15 3 9 QAWeb presets 16 3 10 Display functions 16 3 11 White point selection 17 3 12 Analog video settings 17 3 13 Power save mode 18 3 14 OSD menu language 18 3 15 OSD menu...

Page 4: ...Table of contents 2 K5902137 451920612603 MDRC 1219 23 02 2018...

Page 5: ...s of precautionary or advisory statements that may be used in this user guide In descending order of importance they are WARNING Describes hazards or dangers that might result in personal injury or de...

Page 6: ...signed for this display and is the ideal protection during transport and storage 1 2 Product overview Front 1 3 4 2 Image 1 1 MDRC 1219 and MDRC 1219 TS 1 4 2 Image 1 2 MDRC 1219 HB and MDRC 1219 HB T...

Page 7: ...er clockwise o to scroll up in the OSD menu o to decrease values in the OSD menu 3 Front sensor only for MDRC 1219 and MDRC 1219 TS 4 Power status LED Off Display not powered or display is on but powe...

Page 8: ...0 upstream connector 3 USB A 2 0 downstream connectors 2x for MDRC 1219 and MDRC 1219 TS 4 DisplayPort video input 5 Earth pin 6 DVI I video input 7 100 240 VAC mains power input IEC C14 8 Height adju...

Page 9: ...AUTION When the display is assembled in the medical system take care of the fixa tion of all cables to avoid unwanted detachment CAUTION The monitor is not intended to be sterilized 2 1 Cable connecti...

Page 10: ...ost to make use of QAWeb or any of the display USB downstream connectors e g to connect a keyboard mouse or other peripheral Image 2 3 MDRC 1219 and MDRC 1219 TS Image 2 4 MDRC 1219 HB and MDRC 1219 H...

Page 11: ...G18 wire maximum admitted cable length according to national regulation requirements Image 2 7 MDRC 1219 and MDRC 1219 TS Image 2 8 MDRC 1219 HB and MDRC 1219 HB TS 5 Route all cables through the prov...

Page 12: ...t is landscape If you use the display in portrait mode make sure you change the orientation of the video input via the screen settings of the computer 2 3 VESA mount installation To mount the display...

Page 13: ...panel from the stand Image 2 10 2 Use 4 M4 screws to attach the panel to a VESA approved arm Please respect the following rule to select an appropriate screw length Lmin T W 8 mm Lmax T W 14 mm T W Lm...

Page 14: ...2 Installation 12 K5902137 451920612603 MDRC 1219 23 02 2018...

Page 15: ...n saver displays moving content In case you are working with the same image or an application with static image elements for several hours continuously so that the screen saver is not activated change...

Page 16: ...l to go into a submenu or confirm adjustments and selections 3 4 Power status LED Overview The power status of the display is indicated by a LED at the front of the display Below is an overview of the...

Page 17: ...OSD main menu 2 Navigate to the Input selection menu 3 Select one of the available input sources and confirm 3 7 Luminance adjustment To adjust the luminance 1 Bring up the OSD main menu 2 Navigate t...

Page 18: ...ined These functions emphasize on these parts containing crucial diag nostic information by correcting the native panel behavior The available display functions for your MDRC 1219 are Native If you se...

Page 19: ...lm color temperature Clearbase Simulation of the clearbase film color temperature Programmable When selecting this setting you will be able to manually adjust the video gain for the red green and blue...

Page 20: ...14 OSD menu language About the OSD menu language By default the OSD menu comes up in English However there s a wide range of other languages avail able for the OSD menu of your MDRC 1219 To select th...

Page 21: ...r the Factory Reset submenu 4 Select Yes or No as desired and confirm 3 17 Touchscreen About touchscreen This is only applicable for the MDRC 1219 TS and MDRC 1219 HB TS options Touchscreen is interfa...

Page 22: ...3 Operation 20 K5902137 451920612603 MDRC 1219 23 02 2018...

Page 23: ...essive pressure on the front glass or LCD CAUTION Do not apply or spray liquid directly to the display as excess liquid may cause damage to internal electronics Instead apply the liquid to a cleaning...

Page 24: ...Strong alkalis lye strong solvents Acid Detergents with fluoride Detergents with ammonia at higher concentration 1 6 Detergents with abrasives Steel wool Sponge with abrasives Steel blades Cloth with...

Page 25: ...xide The equipment shall not be operable when the air oxygen content is above 25 Non patient care equipment Equipment primarily for use in a health care facility that is intended for use where contact...

Page 26: ...which has been approved and complies with the safety standard of your particular country Grounding reliability Grounding reliability can only be achieved when the equipment is connected to an equival...

Page 27: ...application level it is necessary to foresee a backup unit in case the video falls away National Scandinavian Deviations for CL 1 7 2 Finland Laite on liitett v suojamaadoituskoskettimilla varustettuu...

Page 28: ...dous substances that Barco s product may contain The RoHS of Chinese Mainland is included in the MCV standard of the Ministry of Information Industry of China in the section Limit Requirements of toxi...

Page 29: ...cture and the specifications of this device as well as the materials used for manufacturing makes it easy to wipe and clean and therefore suitable to be used for various applications in hospitals and...

Page 30: ...ay cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this device does cause harmful interference to radi...

Page 31: ...relocate the receiving antenna or equipment Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is c...

Page 32: ...hould be at levels characteristic of a typical location in a typical commercial or hospital environment Conducted RF IEC 61000 4 6 Radiated RF IEC 61000 4 3 3 V m 150 kHz to 80 MHz 9 to 28 V m in comm...

Page 33: ...1 2 P 80MHz to 800MHz d 1 2 P 800MHz to 2 5GHz d 2 3 P 0 01 0 12 0 12 0 23 0 1 0 38 0 38 0 73 1 1 2 1 2 2 3 2 Field strengths from fixed transmitters such as base stations for radio cellular cordless...

Page 34: ...er supply you may find the following symbols nonrestrictive list Indicates the device meets the requirements of the applicable EC directives Indicates compliance with Part 15 of the FCC rules Class A...

Page 35: ...ndicates the temperature limitations5 for the device to safely operate within specs Indicates the device serial number Indicates the device part number or catalogue number Warning dangerous voltage Ca...

Page 36: ...tical boxes which may be stacked on each other where n is the limiting number xx yy Kg or xx yy xx yy Indicates the weight of the box and that it should be carried with two persons Indicates that the...

Page 37: ...ocument is copyrighted All rights are reserved Neither this document nor any part of it may be reproduced or copied in any form or by any means graphical electronic or mechanical including photocopyin...

Page 38: ...W x H x D 426 x 592 x 326 mm Net weight with stand 5 3 kg Net weight w o stand 3 1 kg Net weight packaged 8 1 kg Tilt 5 to 22 Pivot 90 Height adjustment range 110 mm Mounting standard VESA 100 mm Rec...

Page 39: ...g angle H V 178 Ambient light presets Yes reading room selection Front sensor Yes Front Consistency Sensor Maximum luminance panel typical 330 cd m DICOM calibrated luminance 250 cd m Contrast ratio p...

Page 40: ...CSA C22 2 No 60601 1 14 IEC 60529 1991 A1 2000 Degrees of protection IP code IEC 60601 1 2 2014 FCC class B ICES 001 Level B CCC GB9254 2008 GB4943 1 2011 GB17625 1 2012 VCCI KC Supplied accessories...

Page 41: ...yPort USB ports 1x USB 2 0 upstream endpoint 1x USB 2 0 downstream Power requirements Internal power supply 100 240 Vac 50 60 Hz Power consumption 20 W nominal 0 5 W standby OSD languages English Germ...

Page 42: ...0 C Operating humidity 20 to 80 non condensing Storage humidity 10 to 90 non condensing Operating pressure 70 kPa minimum Storage pressure 50 to 106 kPa MDRC 1219 HB TS Screen technology AHVA TFT Colo...

Page 43: ...408 518 x 201 mm Dimensions w o stand W x H x D 411 x 348 x 67 mm Dimensions packaged W x H x D 426 x 592 x 326 mm Net weight with stand 6 2 kg Net weight w o stand 4 kg Net weight packaged 8 2 kg Til...

Page 44: ...rs Operating temperature 0 C to 40 C Storage temperature 20 C to 60 C Operating humidity 20 to 80 non condensing Storage humidity 10 to 90 non condensing Operating pressure 70 kPa minimum Storage pres...

Reviews: