Page 1: ..._________________________________________________________ Manual 26 1302001 00 Revision 01 MatrixPRO II DVI 16x16 Matrix Router User s Guide ...

Page 2: ...antee On receipt the purchaser must immediately inspect all delivered goods for damage incurred during transport as well as for material and manufacturing faults Barco must be informed immediately in writing of any complaints The period of guarantee begins on the date of transfer of risks in the case of special systems and software on the date of commissioning at latest 30 days after the transfer ...

Page 3: ...e as comments or examples and are not to be understood as advertising for the products or their manufactures __________________________________________________________________ Company Address Barco Inc 11101 Trade Center Drive Rancho Cordova California 95670 USA Phone 916 859 2500 Fax 916 859 2515 Barco N V Noordlaan 5 8520 Kuurne BELGIUM Phone 32 56 36 82 11 Fax 32 56 35 16 51 Website www barco c...

Page 4: ...onductor in the power cord is essential for safe operation Grounding the Product This product is grounded through the grounding conductor of the power cord To avoid electrical shock plug the power cord into a properly wired receptacle before connecting to the product input or output terminals A protective ground connection by way of the grounding conductor in the power cord is essential for safe o...

Page 5: ...Wartungsanweisungen in der Dem Great beiliegenden Literatur aufmerksam zu machen Disposal of the Product wast Electrical and Electronic Equipment This symbol on the product indicates that under the European Directive 2002 96 EC governing waste from electrical and electronic equipment this product must not be disposed of with other municipal waste Please dispose of your waste equipment by handing i...

Page 6: ...毒有害 有毒有害 有毒有害物 物 物 物质 质 质 质或元素 或元素 或元素 或元素 Hazardous Substances or Elements 铅 铅 铅 铅 Pb 汞 汞 汞 汞 Hg 镉 镉 镉 镉 Cd 六 六 六 六价 价 价 价铬 铬 铬 铬 Cr6 多溴 多溴 多溴 多溴联 联 联 联苯 苯 苯 苯 PBB 多溴二苯醚 多溴二苯醚 多溴二苯醚 多溴二苯醚 PBDE 印制 印制 印制 印制电 电 电 电路 路 路 路配 配 配 配件 件 件 件 Printed Circuit Assemblies O O O O O O 插入 插入 插入 插入式 式 式 式印制 印制 印制 印制电 电 电 电路 路 路 路配 配 配 配件 件 件 件 Plug in Printed Circuit Assembly O O O O O O 外接 外接 外接 外接电 电 电 电 线 线 线...

Page 7: ...arco Barco Barco产 产 产 产品所采用的 品所采用的 品所采用的 品所采用的EFUP EFUP EFUP EFUP标签 标签 标签 标签 请参阅实 请参阅实 请参阅实 请参阅实例 例 例 例 徽 徽 徽 徽标内 标内 标内 标内部的 部的 部的 部的编号 编号 编号 编号使用于制 使用于制 使用于制 使用于制 定 定 定 定产 产 产 产品 品 品 品 基于中 基于中 基于中 基于中国 国 国 国大 大 大 大陆 陆 陆 陆的 的 的 的 电 电 电 电子信息 子信息 子信息 子信息产 产 产 产品 品 品 品环 环 环 环保使用期限通 保使用期限通 保使用期限通 保使用期限通则 则 则 则 标 标 标 标准 准 准 准 All Electronic Information Products EIP that are sold within Chinese Mainland...

Page 8: ...Router ________________________________________________________________________ User s Guide Rev 01 8 CHANGE HISTORY Rev Date ECP Description Approved By 00 6 7 13 606947 User s Guide GKOU 01 7 29 13 608395 User s Guide MYRA ...

Page 9: ...T 18 4 4 FUNCTION mode 18 4 4 1 Gateway 19 4 4 2 Subnet Mask 19 4 4 3 IP Address 19 4 4 4 MAC Address 20 4 4 5 UDP Port Number 20 4 4 6 Video Generator 20 4 4 7 Monitoring Output 20 4 4 8 EDID Configure 20 4 4 9 HDCP Configure 22 4 4 10 Baud Rate 23 4 4 11 Control Lock 23 4 4 12 Reset Mode 23 5 PC Program Operation 24 5 1 Basic Setup 24 5 1 1 Connect Info 25 5 1 2 Channel Name 26 5 1 3 Video Gener...

Page 10: ... 01 10 7 2 2 Input and output status 32 7 2 3 Network setting 33 7 2 4 Monitor output port setting 33 7 2 5 EDID control command 33 7 2 6 HDCP Setting 34 7 2 7 Baud rate setting for RS 232 34 7 2 8 Control lock command 35 8 Firmware update 36 9 HDCP notes 40 10 Specifications 41 11 Warranty 42 12 Contact Information 43 ...

Page 11: ...ault Mode Auto Mix Mode Output Copy Mode Supports various control methods Front panel button operation Command input Through RS 232 and Telnet connections Built in web panel control TCP IP PC program by RS 232 and UDP Supports entire family of Barco Encore Controllers Dual hot swappable power supplies for power redundancy and load sharing Redundant supply is optional Barco part number R767420K Dia...

Page 12: ... the equipment in a manner not specified by the manufacturer may result in irrecoverable damage Keep the unit away from liquid magnetic and combustible substances Do not place heavy weight on the unit Do not install the unit in a hazardous location i e high vibration or impact risk Do not install the unit vertically Do not disassemble the unit To turn the unit off completely unplug the AC power co...

Page 13: ...ll Input and output cards interface ports and power supplies are placed on the rear panel as shown below Input bay for 4 input cards left side Output bay for 4 output cards right side SERVICE RJ 11 receptacle for firmware upgrades RS 232 Serial communication port LAN RJ 45 receptacle for TCP IP or UDP control REFERENCE OUTPUT provides an internal test pattern video source MONITORING OUTPUT provide...

Page 14: ...splay size luminance data and for digital displays only pixel mapping data Once the graphic source reads the information set usually during the booting process the EDID conveys the optimal format for a connected display The MATRIXPRO II DVI supports storing EDID information to an EEPROM for each Input The MATRIXPRO II DVI has three methods to set EDID values 1 Default Mode default EDID information...

Page 15: ...uts is created and used to avoid any compliance problems in the field Figure 2 1 EDID operation As depicted in the Figure once the EDID is configured each EDID is stored in EEPROM in Input ports As a result the video sources can read the EDID information from the EEPROM during booting process EEPROM1 EEPROM2 EEPROM3 EEPROM16 EDID INTERFACE CONTROL Read Write Sources INPUT 1 16 Displays OUTPUT 1 16...

Page 16: ...lect Local Area Connection and right click to open property Select Internet Protocol Version 4 TCP IPv4 Enter IP Subnet mask Gateway and DNS server address compatible with the current network setting of MATRIXPRO II DVI 16x16 Click OK to terminate IP setup session 3 1 1 Launching Telnet Telnet is a terminal program embedded in Window OS system to access remote computers using TCP IP protocol With ...

Page 17: ... Code and Phone Number fields but select available COM port of PC and then click OK In COM Properties window set the parameters as below Bits per second baud rate 115200 115200 is default baud rate of MATRIXPRO II DVI 16x16 Data bits 8 Parity None Stop bits 1 Flow control None Click OK to save the parameters Go Start Programs Accessories Communications HyperTerminal then new icon will be shown The...

Page 18: ...NLINK mode It unlinks input output connection 1 Press LINK key button 2 Press SHIFT key button UnLINK should now be displayed 3 Press the input key button for the routing you would like to clear 4 Press ENTER key button 4 3 PRESET mode SHIFT ON PRESET The Preset function is currently unavailable This feature will be added in the future 4 4 FUNCTION mode This function enables the configuration of t...

Page 19: ...8 000 001 4 4 2 Subnet Mask The cursor shows that it is selected and activated Input 3 key button decreases the number Input 4 key button increases the number Input 1 and 2 key buttons move the cursor left and right Subnet Mask O 255 255 255 000 N 255 255 255 000 Modify the Subnet mask address to be used for your network Press ENTER key button to complete the process The default setting is 255 255...

Page 20: ...d Input 3 key button decreases the number Input 4 key button increases the number Monitoring Output Old Input 01 New Input 01 1 Connect a display to the Monitoring Output port and any video sources to the DVI input ports on the real panel 2 Select an input port by pressing input 3 or 4 key button 3 Press ENTER key button to complete the process 4 4 8 EDID Configure Sets the EDID information in inp...

Page 21: ...e Default EDID to allocated input as below EDID Configure EDID Copying EDID Reading 3 2 If you select Auto Mix Mode mixed EDID of all attached displays will be saved in allocated input 3 3 If you select Output Copy Mode MATRIXPRO II DVI 16x16 reads EDID from any target displays and copies it in allocated input New EDID can be created or existing EDID can be modified using the Edit Data Mode This f...

Page 22: ...s occurred at times when outputting content from an Apple MacBook Pro via a mini DisplayPort to a DVI adapter In order to allow the use of sources such as the MacBook Pro to display non HDCP protected data for example the show graphics with standard non HDCP compliant displays we have added the ability to disable HDCP compatibility in the MATRIXPRO II DVI 16x16 Router Please note that this new fea...

Page 23: ...NTER key button to complete the process The default setting is 115200 4 4 11 Control Lock Locks and unlocks the controls such as Web RS 232 TCP IP UDP and key button Control Lock Web Lock UnLock Data Lock UnLock Key Lock UnLock Input 1 and 2 key buttons move the cursor up and down Input 3 key button moves Lock Input 4 key button moves UnLock Press ENTER key button to complete the process 4 4 12 Re...

Page 24: ... program for MATRIXPRO II DVI 16x16 The PC program provides a user friendly graphic interface alternative to key button input and command input operation Copy MPII DVIsetup exe file in any directories in your PC and double click it to run The initial window of PC program for MATRIXPRO II DVI 16x16 as shown below will appear 5 1 Basic Setup Click Set Config button to set the communication method in...

Page 25: ...select baud rate The baud rate of your PC should be the same as the MATRIXPRO II DVI 16x16 baud rate 115200 is default For Ethernet control enter the IP address of the MATRIXPRO II DVI 16x16 and port number 3000 is the default port number for the MATRIXPRO II DVI 16x16 Click save button and close Set Config window then click Connect button on PC program of MATRIXPRO II DVI 16x16 to start it If the...

Page 26: ...rator Click Apply button to save it 5 1 4 Control Lock Mode Locks and unlocks the controls such as Web Data control RS 232 TCP IP and UDP and key button input Click Apply button to save it 5 1 5 Network Changes the network information of MATRIXPRO II DVI 16x16 Click Apply button to save it 5 2 EDID setup MATRIXPRO II DVI 16x16 offers 3 types of EDID settings for easy installation with various disp...

Page 27: ...el first and then click the input channels Click the Apply button to save settings Edit Data Mode is used to modify existing EDIDs or to make a new custom EDID This feature is recommended for advanced users only 5 3 Operation The communication settings and system status are on the right side of the control application as shown below After clicking the Connect button Refer to Chap 4 1 1 the MatrixP...

Page 28: ...d to outputs 05 06 07 and 08 as shown in Fig 4 5 To connect one input to all outputs click All Link button and click desired input Then all of the outputs will be connected to the selected input To disconnect all outputs click the Link Clear button 5 3 2 Input channel status Green LEDs above the input channel numbers indicate that a signal has been detected In fig 4 5 above CH05 and CH10 have dete...

Page 29: ...__ User s Guide Rev 01 29 5 3 3 Output channel status Green LEDs above the output channel number indicate Hot Plug Detection HPD from display For example CH07 is connected to a display The connected outputs show input source information ex CH07 Camera 1 input CH05 The disconnected outputs show No Link ...

Page 30: ...ch the web browser and enter the IP address of current MATRIXPRO II DVI 16x16 into the URL address line For example 192 168 0 246 Fig 6 1 shows structure of Web control panel It controls input output connection video generator and informs simple input output status Reminder after new input output connection user has to click LINK button and SEND button for new generator setting Microsoft Explorer ...

Page 31: ...d of a string of ASCII codes and its basic structure is Command Delimiter Data Delimiter or or _ Data End Table 6 1 shows all commands and its brief descriptions Command Description LINK Input and Output connection IN Input signal status request OUT Output signal status request NET Network information request NETGW Gateway address setting NETSN Subnet mask address setting NETIP IP address setting ...

Page 32: ...Makes input 1 connected to output 10 Reply LINK 01 10 LINK 1 03 04 7 Makes input 1 connected to output 3 and 4 to 7 Reply LINK 01 03 04 07 LINK 05 Makes input 5 connected to all outputs Reply LINK 05 LINK 00 Makes all connections disconnected Reply LINK 00 LINK 00 06 Makes output 6 disconnected Reply LINK 00 06 Link Requests current inputs and outputs connections status Reply LINK 01 01 02 04 16 1...

Page 33: ...om 00 to FF Reply NETPA AA BB CC DD EE FF NETPT 3000 Sets UDP port number data ranges from 0 to 65535 NETPT 3000 NET Requests current network setting Reply NETGW 192 168 001 001 NETIP 192 168 001 118 NETSN 255 255 255 000 NETPA AA BB CC DD EE FF NETPT 3000 Table 7 4 Network setting command examples 7 2 4 Monitor output port setting Makes an input connected to the Monitor Output port Requests input...

Page 34: ...ID OUT3_5 Output copy mode Copies EDID information of output 3 display and stores it in input port 5 Reply EDID 03OUT EDID Requests current EDID setting for all inputs Reply EDID 01OUT 02AUTO03OUT 16EDF Table 7 6 Monitor output setting command examples 7 2 6 HDCP Setting Allows the user to turn HDCP On or Off for any of the 16 input ports Command Description and reply HDCP Retrieves HDCP setting f...

Page 35: ... 115200BPS Table 7 7 Baud rate setting command examples 7 2 8 Control lock command Locks and unlocks the controls such as Web RS 232 TCP IP and UDP Requests open status of controls ASCII Description WL Web control lock WUL Web control unlock DL Data control UDP TCP IP RS 232 lock DUL Data control UDP TCP IP RS 232 unlock KL Key control lock KUL Key control unlock Table 7 9 Locking type and its ASC...

Page 36: ... 36 8 Firmware update 1 Using a Windows XP based PC install the megaboot exe program provided on a CD 2 Click Open of File to be programmed in the Flash to select directory and file hex Format to be uploaded You can run Megaboot exe with Windows 7 as an Administrator Alternatively you can run Megaboot exe under Windows XP ...

Page 37: ...x 16 to a RS 232 Comm port on a PC using the supplied download cable RJ1 1 to D Sub 9Pin cable 4 Select Comm port to select communication port of PC for RS 232 communication with MATRIXPRO II DVI 16x16 5 To enable Comm port Click when it shown as Serial Port Enable 6 Power On the MATRIXPRO II DVI 16x16 7 The firmware upload should then begin and the status will be shown in the message box as shown...

Page 38: ...II DVI 16x16 Router ________________________________________________________________________ User s Guide Rev 01 38 8 After 1 to 2 minutes and All Done message will be shown Then the firmware upload is completed ...

Page 39: ... DVI 16x16 Router ________________________________________________________________________ User s Guide Rev 01 39 9 Close the MegaBoot exe program and reboot MATRIXPRO II DVI 16x16 to run it under the new firmware ...

Page 40: ...e required protection For proper implementation products that are compatible with the HDCP format require a secure connection to a compliant display such as a projector or monitor In applications in which the DVI router is used when an HDCP compliant device is connected to the router an HDCP session is created In this session which is transparent to the user keys are exchanged between the source d...

Page 41: ...ink DVI digital formats up to 165 Mhz per DVI 1 0 specification Reference and Monitor Formats all single link DVI digital formats up to 165 Mhz per DVI 1 0 specification Physical and Electrical Specifications Control Ethernet RJ 45 10 100 Mbps autosense Height 7 in 178 mm 4RU Width 17 32 in 440 mm Depth 14 96 in 380 mm Weight 10 kg Input power 100 240 VAC 50 60 Hz 800 watts max each supply Environ...

Page 42: ...ghtning strikes abuse drop crush and or other unusual damages The customer shall pay shipping charges when unit is returned for repair Barco will cover shipping charges for return shipments to customers Return Material Authorization RMA In the unlikely event that a product is required to return for repair please call the Technical Support Customer Service direct line and ask to receive a Return Me...

Page 43: ...ebsite www barco com Sales Contact Direct 916 859 2505 Toll Free 888 414 7226 E mail folsomsales barco com Barco N V Noordlaan 5 8520 Kuurne BELGIUM Telephone 32 56 36 82 11 Fax 32 56 35 16 51 Website www barco com Technical Support USA Telephone 866 374 7878 6 a m to 10 p m PST 7 days per week E mail folsomsupport barco com Online www barco com esupport Technical Support Europe Middle East Asia T...