ImagePRO-II • User’s Guide
17
3. Hardware Installation
Cable and Adapter Information
•
Rack mount each ImagePRO-II chassis from the front rack ears using four rack
screws (not supplied). Rack threads may be metric or otherwise — depending
upon the rack type.
•
Install the
lower
of the two mounting holes first.
`~ÄäÉ=~åÇ=^Ç~éíÉê=fåÑçêã~íáçå
The table below provides information regarding cables used with the ImagePRO-II. When
connecting to an ImagePRO-II, use high-quality shielded cables.
mçïÉê=`çêÇ=~åÇ=iáåÉ=sçäí~ÖÉ=pÉäÉÅíáçå
The ImagePRO-II is rated to operate with the following specifications:
Input Power:
100-240 VAC, 50-60 Hz
Power Consumption:
100 Watts maximum
The ImagePRO-II performs line voltage selection automatically. No user controls are
required. The AC power cords must be accessible so that they can be removed during field
servicing.
Table 3-1.
ImagePRO-II System Cables
Cable
Description
Note
Remote Connections
RJ-45 Ethernet Cable
For use with optional Encore or ScreenPRO-II Controller
or ImagePRO-II Web Interface
Customer Supplied
Power Connections
AC Power Cord
AC Power, 7 foot, 10A
1 Cord Supplied
Warning
When the ImagePRO-II is used in the
230-volt mode, a UL listed line cord
rated for 250 volts at 15 amps must be
used and must conform to IEC-227 and
IEC-245 standards. This cord will be
fitted with a tandem prong-type plug.
The rear panel ON/OFF switch does not
disconnect the unit from input AC power.
To facilitate disconnection of AC power,
the power cord must be connected to an
accessible outlet near the unit.
Building Branch Circuit Protection
:
For 115 V use 20 A. For 230 V use 8 A.