3. Physical installation
A
F
F
G
B
D
E
C
E
Image 3-19
A
Power linking cable.
B
Power input port.
C
Power link to next tile (C19 plug).
D
Power link from previous tile (C20 plug).
E
Data input/output linking cable.
F
DVI input/output connector.
G
Resync-unit.
3.6.2
Power cabling
3.6.2.1
Connections with a Mono Phase Power Box
Necessary parts
•
ILite Mono Phase Power Box.
•
Power linking cables.
•
Cable ties.
Power connections
1. Attach the ILite Mono Phase Power Box to the rear side of the ILite display.
2. Start creating power branches by connecting the output cables of the power box with the power linking cable of the lowest tile in
a column of maximum six. (image 3-20)
3. Complete each power branch by connecting maximum six tiles with power linking cables to each other in a daisy chain manner.
The female C13 plug of the power linking cable is plugged directly in the tile. The male C20 and the female C19 plugs serve as
power loop through. The last female C19 plug in the chain is unused.
Warning:
Maximum 6 (six) tiles per power branch are allowed. Connecting more then six tiles with one output cable will over-
load the circuit.
4. Attach long cables with cable ties to the frame.
5. Connect the power box with the local power-net. In case the local power net is not provided with a earthwire an additional earth
connection must be installed and connected with the protected earth inside the power box.
R5976522 FIXED ILITE DISPLAY 05042004
29