3.3
Power input setup of the HDQ 4K35
About the power input
The projector power input can be con
fi
gured for a power supply of 230/400V 3W+N+PE (
Υ
-connection) or for 208V 3W+PE (
Δ
-con-
nection). Before operating the projector, place the links in the correct position depending on the local power supply.
For a 3W+N+PE system, 400V is measured between the lines, 230V is measured between the lines and the neutral.
For a 3W+PE system, 208V is measured between the lines.
A
B
Image 3-4
Υ
-
Δ
connection
A
Υ
connection
B
Δ
connection
Necessary tools
•
Flat screw driver
•
Wrench 10 mm
•
Torque wrench 10 mm
How to switch from a
Υ
-connection to
Δ
-connection
1. Loosen the 6 top nuts on the
Υ
/
Δ
con
fi
guration block. (1 to 6)
Y
Δ
1
2
3
4
5
6
B
A
C
Image 3-5
Υ
to
Δ
connection
2. Take off the mounted lins (A, B and C). Two links above each other or mounted between the upper and middle pin (A, B) and one
link between the middle pin and lower pin (C).
3. Mount the links horizontally on the pins.
4. Turn a nut on each pin and secure with a torque wrench set to
7.5 Nm
.
How to switch from a
Δ
-connection to
Υ
-connection
1. Loosen the top nuts on the
Υ
/
Δ
con
fi
guration block (1 to 6).
20
R5905823 HDQ 4K35 30/11/2015
Summary of Contents for HDQ 4K35
Page 1: ...HDQ 4K35 User and Installation manual R5905823 04 30 11 2015 ...
Page 4: ......
Page 58: ...4 Lenses Lens Holder 54 R5905823 HDQ 4K35 30 11 2015 ...
Page 69: ...6 Starting up 6 STARTING UP R5905823 HDQ 4K35 30 11 2015 65 ...
Page 70: ...6 Starting up 66 R5905823 HDQ 4K35 30 11 2015 ...
Page 84: ...7 Maintenance 80 R5905823 HDQ 4K35 30 11 2015 ...
Page 96: ...8 Removal and installation of the projector covers 92 R5905823 HDQ 4K35 30 11 2015 ...
Page 98: ...A Dimensions and specifications 94 R5905823 HDQ 4K35 30 11 2015 ...
Page 108: ...B Environmental information 104 R5905823 HDQ 4K35 30 11 2015 ...