background image

BARCO PROJECTION SYSTEMS

Date :
060199

INSTALLATION MANUAL

KIT LAMP FOR 6300 PROJECTORS

R9829900

Art. No. :

R5975949

Rev :

01

Lamp 6300

Kit

Summary of Contents for Graphics 6300

Page 1: ...BARCO PROJECTION SYSTEMS Date 060199 INSTALLATION MANUAL KIT LAMP FOR 6300 PROJECTORS R9829900 Art No R5975949 Rev 01 Lamp 6300 Kit ...

Page 2: ... Produced by BARCO NV January 1999 All rights reserved Trademarks are the rights of their respective owners BARCO n v Projection Systems Noordlaan 5 B 8520 Kuurne Belgium Tel 32 56 368211 Fax 32 56 351651 E mail sales bps barco com Visite Barco at the web http www barco com Printed in Belgium ...

Page 3: ...h temperature and high pressure 20 bar which may explode suddenly There is a risk of personal injury and property damage from hot quartz arc tube particles if handled incorrectly Risk of Electrical Shock Power down the projector and unplug the power cord from the wall outlet Once the projector is cooled down and the power is off continue with the replacement procedure Lamp Life Time Warning The to...

Page 4: ...f the lamp is touched finger prints can be removed by cleaning the lamp with alcohol Part Listing The following parts are in the kit R808017 R5975949 1 FRMC G6300 LMP HSG LMP MAN INS G6300 LMP Part Number Description Indication Lamp Serial Number Each new lamp is marked with a serial number 6 digits Write down this number in the forseen area The serial number has to be programmed when resetting th...

Page 5: ...on cover has to be removed Necessary Tools a flat screwdriver 5 mm Opening the Lamp House Door To open the lamp house door follow the next procedure 1 2 3 1 2 Turn with a screwdriver a quarter turn counter clockwise Open the door a little Unhook the door from its fixing points Step Action Image Illustrations on Opening the Lamp House Door Image 1 Image 2 ...

Page 6: ...ure 1 2 3 1 Loosen with a screwdriver the four indicated bolts Pivote the plate a little downwards Take out the protection cover Step Action Image Caution Hot surface Do not touch rotating fan blades High pressure lamp may explode if improperly handled Refer servicing to qualified service personnel Illustrations on Removing the Protection Cover ...

Page 7: ...re necessary Disconnecting the Lamp Power Cable To disconnect the lamp power cable follow the next procedure 1 2 3 4 1 2 Pull out the connector Take the connector between thumb and finger Push at the same time on both looking parts Unplug the connectors Step Action Image Illustrations on Disconnecting the Lamp Power Cable The following images give an overview how to discoonect the power cable imag...

Page 8: ... Assembly To remove the lamp assembly follow the next procedure 1 2 1 Slide the lamp assemble backwards Take out the lamp assembly Step Action Image Illustrations on Removing the Lamp Assembly The following image gives an illustration on how to slide out the lamp image 1 image 2 ...

Page 9: ... lifetime of the lamp will be reduced If the lamp is touched finger prints can be removed by cleaning the lamp with alcohol Installing the Lamp Assembly To install the lamp assembly follow the next procedure 1 2 3 1 2 Take the lamp assembly out of its package Put the lamp assembly in the lamp house Slide the lamp assemble forwards until fits on its place Step Action Image Illustrations on Installi...

Page 10: ...lustrations on Connecting Lamp Power Cable Reinstall the Lamp Power Cable To reinstall the lamp power cable follow the next procedure 1 2 Connect the connector at the lamp side into the connector at the power side Put the connector under the metal slip Step Action 1 1 Image ...

Page 11: ...d The lamp house door has be closed Necessary Tools a flat screwdriver 5 mm or a nutdriver 5 5 Installing the Protection Cover To install the protection cover follow the next procedure 1 2 1 Put the protection cover on its place Turn in with a screwdriver the four indicated bolts Step Action Image Illustrations on Removing the Protection Cover ...

Page 12: ...losing the Lamp House Door To close the lamp house door follow the next procedure 1 2 3 1 2 Hook the door on its fixing points Close the door Turn with a screwdriver a quarter turn clockwise Step Action Image Image 1 Image 2 Illustrations on Closing the Lamp Door ...

Page 13: ...y Tools a flat screwdriver 5 mm Removing the Dust Filter To remove the dust filter follow the next procedure 1 2 3 4 5 1 2 Turn the projector upside down Turn out both screws of both dust filters Clean the dust filter with a dry cloth Re insert the dust filter Turn in both screws of both dust filters to secure their position Step Action Image Illustrations Image 1 Image 2 ...

Page 14: ...set Run Time menu appears Enter the serial number of the new lamp with the digit keys on the RCU Start with 0 and continue with the number written on page 4 Press ENTER to continue Step Action Screen menu SERVICE IDENTIFICATION CHANGE PASSWORD CHANGE LANGUAGE CHANGE PROJ ADDRESS CHANGE BAUDRATE PC RESET LAMP RUNTIME LAMP RUNTINE HISTORY LAMP DRIVE MODE MORE ADJUSTMENT MODE Select a path from below...