3. Installation Guidelines
Image 3-5
Safety Area
3.6 Re-adjusting the lamp position in the lamp casing
W
ARNING
:
As the projector has to be opened, this procedure has to be performed by qualified service tech-
nician.
Why
With higher run times, the light output of the lamp will decrease, which results in a lower light output on the screen. This light output
decrease can be compensated by readjusting the position of the lamp.
A suggestion dialog box will be displayed when the projector is restarted after 100 hours and 250 hours. Once
ENTER
is pressed
when that box is open, this box will not be displayed again till the next alert point is reached.
Suggestion
Lamp runtime is
105 hours
It is advisable to
adjust the Z-axis
of the lamp to
obtain maximum
light output
(see owners manual)
<ENTER> to confirm
Menu 3-1
The user can now adjust the Z-axis by following the next procedure.
How to readjust.
1. On the side of the inputs, turn the retaining bolt a quarter counter clockwise.
2. Flip the cover to the left side and take off. (image 3-6)
3. Start up the adjustment mode and select
Service
. (menu 3-2)
4. Select Lamp. The Z-axis indication (lamp menu in service mode) will be helpful while turning screw B . (menu 3-3)
5. Loosen the nut A (image 3-7)on the back of the lamp casing (nutdriver 10).
14
R5976698 BARCO GALAXY WARP™ 10 HB 05/04/2004
Summary of Contents for Galaxy WARP 10 HB
Page 1: ...Barco Galaxy WARP 10 HB Owner s Manual R9040330 R5976698 00 05 04 2004...
Page 4: ......
Page 8: ...Table of contents 4 R5976698 BARCO GALAXY WARP 10 HB 05 04 2004...
Page 36: ...4 Connections 32 R5976698 BARCO GALAXY WARP 10 HB 05 04 2004...
Page 43: ...5 Getting Started Image 5 6 RCU to IR Sensors R5976698 BARCO GALAXY WARP 10 HB 05 04 2004 39...
Page 122: ...6 Random Access 118 R5976698 BARCO GALAXY WARP 10 HB 05 04 2004...
Page 150: ...A Standard Source Files 146 R5976698 BARCO GALAXY WARP 10 HB 05 04 2004...