FSN Series • User’s Guide
259
6. System Setup
Tally Setup
q~ääó=pÉíìé
FSN Series system setup:
Step 13
This procedure enables you to assign inputs to the system’s 24 tally relays, set tally
markers, and set individual tally closures.
S
Prerequisite
— Ensure that you are familiar with the following menus and
connector specifications:
~
Tally Setup Menu
~
Tally Connector
— Appendix A, “
Use the following steps to set up tallies:
1.
In the
Menu Bar
, press
{System}
to access the
System Menu
.
2.
Press
{Tally Setup}
to display the
Tally Setup Menu
.
3.
Use the
Select Tally
control to select the tally you wish to set up (
1
through
24
).
4.
Press
{Select Input}
to display the
Input Selection Keypad
. Select the desired
input that you wish to tally, and press
{Apply}
.
5.
Press
{Select Color}
to display the
Select Color Pop-up
, and choose a red,
green or amber color block to identify the tally.
6.
Use the
Select Output
control to select the output for which you want to set a
relay closure. All outputs are grouped in the table.
7.
Press
{Set Tally Closure}
to set a relay closure for the highlighted output. An “
x
”
in the highlighted cell indicates that a closure is set.
8.
Repeat steps
6
and
7
for all outputs that you wish to set tally closures.
9.
Ensure that the physical tally output is properly connected to the target device’s
tally input, e.g., on the camera’s CCU. In Appendix A, refer to the “
” section on page 318 for pinouts.
10.
Repeat from step
3
to set additional tallies.
Use the following steps to clear tallies:
11.
Use the
Select Tally
control to select the tally you wish to clear.
12.
Press
{Clear Input}
to remove the input from the table.
13.
Use the
Select Output
control to select the output that you wish to clear.
14.
Press
{Clear Tally Closure}
to clear the “
x
” from the highlighted output.
15.
Repeat from step
11
to clear additional tallies.
13
Note
Remember that this function is designed only to assist the
engineer who is setting up tallies. It provides a visual menu
indication of the type of tally, but the function does not affect
tally operation.