4. Installation procedures
4.11 Installing the RJ45 IP66 protection shells
The IP66 protection shells can be installed upon the RJ45 plug of standard UTP network cables. The network
cables used between FLX-NNI Controller and FLX-HUB must be of the type UTP cat 6. The maximum length
may not exceed 100 meter.
C
AUTION
:
The network cable which has to be plugged into the RJ45 socket of the FLX-HUB must be equipped
with IP66 protection shells.
How to install the IP66 protection shells on a standard UTP network cable?
1. Align the 7 parts as illustrated.
1
2
3
4
5
6
7
Image 4-17
2. Slide part 1 and 3 over the RJ45 connector.
3. Place the sealing rubber (part 2) over the cable, between part 1 and part 3, and slide it into part 3.
4. Place the O-ring (part 4) over the RJ45 connector into part 3.
5. Place the long sealing rubber (part 5) over the cable between part 3 and the RJ45 plug.
1
2
3
4
5
6
7
Image 4-18
6. Slide the long sealing rubber (part 5) against the RJ45 plug and then slide part 3 against the long sealing rubber.
Image 4-19
7. Place part 6 over the RJ45 plug and fasten with part 7.
Image 4-20
8. Fasten the back end of the shell with part 1.
58
R59770419 FLX-60 12/05/2010
Summary of Contents for FLX-60
Page 1: ...FLX 60 Installation manual R59770419 00 12 05 2010...
Page 6: ...Table of contents 2 R59770419 FLX 60 12 05 2010...
Page 18: ...2 Installation requirements 14 R59770419 FLX 60 12 05 2010...
Page 63: ...4 Installation procedures Image 4 21 R59770419 FLX 60 12 05 2010 59...
Page 64: ...4 Installation procedures 60 R59770419 FLX 60 12 05 2010...
Page 78: ...B Specifications 74 R59770419 FLX 60 12 05 2010...