20. Troubleshooting
20. TROUBLESHOOTING
20.1 Error codes
Overview
When the error code is preceded by a ’-’ sign, then the error means a real error for the projector.
When the error code is preceded by a ’+’ sign, then the error code means a warning. The projector does not fail yet, but take care
for the warning and try to resolve the problem. A warning state can turn into an error state.
Not all error codes can have two states. When the state is available, it is indicated by a Yes in the overview table. When the state
is not available, it is indicated by a No.
Error
code
Description
Error
Warning
Caused by
Action
1000
↓
1017
Wrong lamp
parameters
Yes
-
Wrong lamp/ no communication
with lamp
Check lamp type
Call a quali
fi
ed service engineer
1499
1498
1699
Formatter busy
1698
Formatter
address
1697
Formatter init
failed
Yes
-
no communication with formatter
ctrl
Call a quali
fi
ed service engineer
1696
Formatter ctrl
init failed
Yes
-
no communication with formatter
ctrl
Call a quali
fi
ed service engineer
1695
Red form. start
failed
Yes
-
no communication with red
formatter
Call a quali
fi
ed service engineer
1694
Green form.
start failed
Yes
-
no communication with green
formatter
Call a quali
fi
ed service engineer
1693
Blue form. start
failed
Yes
-
no communication with blue
formatter
Call a quali
fi
ed service engineer
1692
Form.
PWRGood
Yes
-
formatter ’Power Good’ signal not
OK
Call a quali
fi
ed service engineer
2000
No lps detected
Yes
-
no communication with lamp power
supply
Call a quali
fi
ed service engineer
2001
Mains voltage
too low
Yes
-
mains voltage too low
2002
Lamp start
failed
Yes
-
Hot restrike
Lamp with many strikes
maximum run time exceeded
Lamp or LPS or SPG failed
Let cool down the lamp for at least
5 minutes. Retry a few times.
Replace the lamp with a new one
Replace LPS or SPG or cabling.
2003
Main voltage
too high
Yes
-
mains voltage too high
2004
Lamp goes out
Yes
-
Call quali
fi
ed service engineer
2005
Lamp stop
failed
Yes
-
Call quali
fi
ed service engineer
2201
PFC start failed
Yes
-
LPS (address 0x20)
Replace LPS
2501
PFC start failed
Yes
-
LPS (address 0x22)
Replace LPS
2801
PFC start failed
Yes
-
LPS (address 0x28)
Replace LPS
2202
LPS start failed
Yes
-
LPS (address 0x20)
Replace LPS
2502
LPS start failed
Yes
-
LPS (address 0x22)
Replace LPS
R59770180 FLM HD20 11/07/2008
193
Summary of Contents for FLM HD20
Page 1: ...FLM HD20 User guide R59770180 00 11 07 2008...
Page 4: ......
Page 14: ...1 Safety 10 R59770180 FLM HD20 11 07 2008...
Page 46: ...5 Connections 42 R59770180 FLM HD20 11 07 2008...
Page 58: ...6 Getting started 54 R59770180 FLM HD20 11 07 2008...
Page 62: ...7 Start up of the Adjustment Mode 58 R59770180 FLM HD20 11 07 2008...
Page 72: ...8 Input menu 68 R59770180 FLM HD20 11 07 2008...
Page 97: ...9 Image menu Image 9 105 Image 9 106 Image 9 107 R59770180 FLM HD20 11 07 2008 93...
Page 98: ...9 Image menu 94 R59770180 FLM HD20 11 07 2008...
Page 112: ...10 Layout menu Image 10 56 108 R59770180 FLM HD20 11 07 2008...
Page 116: ...11 Lamp menu Image 11 11 Image 11 12 Image 11 13 112 R59770180 FLM HD20 11 07 2008...
Page 156: ...13 Projector control 152 R59770180 FLM HD20 11 07 2008...
Page 190: ...17 Removal of the projector covers 186 R59770180 FLM HD20 11 07 2008...
Page 194: ...18 Dimensions 190 R59770180 FLM HD20 11 07 2008...
Page 204: ...20 Troubleshooting 200 R59770180 FLM HD20 11 07 2008...
Page 212: ...21 Specifications 208 R59770180 FLM HD20 11 07 2008...
Page 214: ...22 Order information 210 R59770180 FLM HD20 11 07 2008...