C. Troubleshooting
C. TROUBLESHOOTING
C.1 Error codes
Overview
When the error code is preceded by a ’-’ sign, then the error means a real error for the projector.
When the error code is preceded by a ’+’ sign, then the error code means a warning. The projector does not fail yet, but take care
for the warning and try to resolve the problem. A warning state can turn into an error state.
Not all error codes can have two states. When the state is available, it is indicated by a Yes in the overview table. When the state
is not available, it is indicated by a No.
Error
code
Description
Error
Warn-
ing
Caused by
Action
1000
↓
1017
Wrong lamp
parameters
Yes
-
Wrong lamp/ no communication
with lamp
Check lamp type
Call a qualified service engineer
1499
1498
1699
Formatter
busy
1698
Formatter
address
1697
Formatter init
failed
Yes
-
no communication with formatter
ctrl
Call a qualified service engineer
1696
Formatter ctrl
init failed
Yes
-
no communication with formatter
ctrl
Call a qualified service engineer
1695
Red form.
start failed
Yes
-
no communication with red
formatter
Call a qualified service engineer
1694
Green form.
start failed
Yes
-
no communication with green
formatter
Call a qualified service engineer
1693
Blue form.
start failed
Yes
-
no communication with blue
formatter
Call a qualified service engineer
1692
Form.
PWRGood
Yes
-
formatter ’Power Good’ signal not
OK
Call a qualified service engineer
2000
No lps
detected
Yes
-
no communication with lamp power
supply
Call a qualified service engineer
2001
Mains voltage
too low
Yes
-
mains voltage too low
2002
Lamp start
failed
Yes
-
Hot restrike
Lamp with many strikes
maximum run time exceeded
Lamp or LPS or SPG failed
Let cool down the lamp for at least
5 minutes. Retry a few times.
Replace the lamp with a new one
Replace LPS or SPG or cabling.
2003
Main voltage
too high
Yes
-
mains voltage too high
2004
Lamp goes out
Yes
-
Call qualified service engineer
2005
Lamp stop
failed
Yes
-
Call qualified service engineer
R5976986 FLM HD18 01/09/2006
169
Summary of Contents for FLM HD18
Page 1: ...FLM HD18 Users manual R9004450 R5976986 00 01 09 2006...
Page 4: ......
Page 44: ...5 Connections 40 R5976986 FLM HD18 01 09 2006...
Page 56: ...6 Getting started 52 R5976986 FLM HD18 01 09 2006...
Page 90: ...9 Image menu 86 R5976986 FLM HD18 01 09 2006...
Page 134: ...13 Projector control 130 R5976986 FLM HD18 01 09 2006...
Page 166: ...17 Removal of the projector covers 162 R5976986 FLM HD18 01 09 2006...
Page 170: ...A Dimensions 166 R5976986 FLM HD18 01 09 2006...
Page 186: ...E Order info 182 R5976986 FLM HD18 01 09 2006...