This button transitions the Preview into Program according to the transition rate. The transition Rate is
transition rate in frames of the native rate.
Four transition types are available: Linear, S-Curve, Logarithmic and Exponential.
Image 6-61: Available transition types
CUT button
Pressing the CUT button immediately presents the Preview to the Program.
6.30 Multiviewer (MVR) Menu
General
The last card slot on the E2 Lite processor may be either a normal Output slot or a dedicated Multiviewer. (See
the description of the Setup tab in
“
Configuration Menu > Adjustment > Unit Configuration
, page 79 for
instructions on how select this slot as either an Output slot or a Multiviewer slot.)
A Multiviewer enables multiple sources (inputs, Backgrounds, outputs) to be displayed on one or two
monitors. Screen Destinations (Program and Preview) can be used up to two times in any Multiviewer Output.
The position of the window for each copy can be different, but the size of the window for each copy is always
the same."
Multiviewer Menu
is the module used to setup the Multiviewer outputs.
Description
This menu is accessible by clicking the Multiviewer icon in the menu bar on the left side of the UI.
The three drop-down menus in the title bar select the system, unit or layout displayed in the multiviewer. For
release one, only one system and one unit are supported.
The Multiviewer page is divided in four parts.
Image 6-62: Multiviewer Menu Overview
Summary of Contents for Event Master E2 Lite
Page 1: ...ENABLING BRIGHT OUTCOMES User s Guide E2 Lite and EC 40...
Page 10: ...R5909934 00 E2 Lite and EC 40 10...
Page 14: ...R5909934 00 E2 Lite and EC 40 14 Introduction...
Page 18: ...R5909934 00 E2 Lite and EC 40 18 Safety...
Page 32: ...R5909934 00 E2 Lite and EC 40 32 General...
Page 46: ...R5909934 00 E2 Lite and EC 40 46 Hardware orientation...
Page 168: ...R5909934 00 E2 Lite and EC 40 168 EM GUI orientation...
Page 208: ...R5909934 00 E2 Lite and EC 40 208 Controller Orientation...
Page 214: ...R5909934 00 E2 Lite and EC 40 214 Controller Configuration...
Page 220: ...R5909934 00 E2 Lite and EC 40 220 Controller Operation...
Page 284: ...R5909934 00 E2 Lite and EC 40 284 E2 Lite Maintenance...
Page 289: ...289 R5909934 00 E2 Lite and EC 40 Environmental Information 15...
Page 300: ...R5909934 00 E2 Lite and EC 40 300 Specifications...
Page 316: ...R5909934 00 E2 Lite and EC 40 316 Remote Control Protocol...
Page 317: ...317 R5909934 00 E2 Lite and EC 40 Troubleshooting C...
Page 320: ...R5909934 00 E2 Lite and EC 40 320 Troubleshooting...