6. Advanced configuration
Barco – Eos Workstation for Windows – DOC-3062-2 – Revision 12 – August-2004
__________________________________________________________________________
6-19
6.2.2
Registry reference
ScreenGeometry
The
ScreenGeometry
value determines the arrangement of the connected O
VER
V
IEW
projection cubes, projec-
tors or monitors.
Name
ScreenGeometry
Typ
DWORD
Value
XXYY00
hex,
XX
= 0..FF,
YY
= 0..FF
Default
0
Effective
after rebooting
Table 6-15
The leading
0x
declares the number to be hexadecimal, the following digits are divided in three groups:
<(XXX)X> <YY> <..>
. The first group determines the number of modules in horizontal direction
X
, the sec-
ond one gives the number in vertical direction
Y
, the third has to be
00
. Only the number of modules exceeding
a 1×1 arrangement is taken into account. Thus an arrangement of 3×2 modules (3 rows, 2 lines) is written as:
00020100
. The leading zeroes however are skipped:
20100
.
The following table lists examples for some arrangements:
lines
rows
1
2
3
4
…
1
00000
10000
20000
30000
2
00100
10100
20100
30100
3
00200
10200
20200
30200
4
00300
10300
20300
30300
…
…
table 6-16
ScreenOrder
The order in which the O
VER
V
IEW
projection cubes, projectors or monitors are assigned to the graphic channels of
E
OS
,
is stored as
ScreenOrder
in the registry.
Name
ScreenOrder
Typ
Binary Value
Value
binary string with up to 256 bytes
Default
000102..FF
Effective
after setting display properties or after rebooting
Table 6-17
The
ScreenOrder
value data are divided in pairs:
<AA><BB><CC><DD>…
. The first pair specifies which chan-
nel is assigned to the first projection cube, the second pair specifies which channel is assigned to the second
projection cube and so on. The projection cubes are counted starting with zero.