R5906848 /04
DP2K SLP Series
373
Code 21310:
“
LDM 1-2
–
lls bank 2 not white point calibrated
”
For this error the same troubleshooting table can be applied to as for code
21309
:
“
LDM 1-2
–
lls bank 1 not
white point calibrated
”
.
Code 21311:
“
LDM 1-2
–
lls bank 3 not white point calibrated
”
For this error the same troubleshooting table can be applied to as for code
21309
:
“
LDM 1-2
–
lls bank 1 not
white point calibrated
”
.
Code 21312:
“
LDM 1-3
–
lls bank 4 not white point calibrated
”
For this error the same troubleshooting table can be applied to as for code
21309
:
“
LDM 1-2
–
lls bank 1 not
white point calibrated
”
.
Code 21313:
“
LDM 1-3
–
lls bank 5 not white point calibrated
”
For this error the same troubleshooting table can be applied to as for code
21309
:
“
LDM 1-2
–
lls bank 1 not
white point calibrated
”
.
Code 21314:
“
LDM 1-3
–
lls bank 6 not white point calibrated
”
For this error the same troubleshooting table can be applied to as for code
21309
:
“
LDM 1-2
–
lls bank 1 not
white point calibrated
”
.
Code 21315:
“
LDM 1-4
–
lls bank 7 not white point calibrated
”
For this error the same troubleshooting table can be applied to as for code
21309
:
“
LDM 1-2
–
lls bank 1 not
white point calibrated
”
.
Code 21316:
“
LDM 1-4
–
lls bank 8 not white point calibrated
”
For this error the same troubleshooting table can be applied to as for code
21309
:
“
LDM 1-2
–
lls bank 1 not
white point calibrated
”
.
Code 21335:
“
LPT 1 - lls bank 9 cold side temperature too high
”
Situation
Solution
Ambient temperature too high.
Check the ambient temperature at the air inlets of the projector. Make sure
the projector operates within specs.
Blocked filters at the air inlets
of the projector.
Clean the front filter or replace with new one. See
“
Wiring issue.
Check / reseat the wiring between the Peltier Control Board and the small
interconnection boards of the Light Source. Replace the wiring if
necessary.
Insufficient cooling of light
source
Check the tube connections between both the Light Source cooler and the
light source. Make sure the tubes are properly connected.
Malfunction Peltier Control
Board
Replace the Peltier Control Board. See
Replacing the Peltier Controller
,
Malfunction Light Source
Replace the light source. See service procedure
“
, page 59.
Code 21336:
“
lpt 1 - lls bank 9 cold side temperature sensor shorted
”
Situation
Solution
Malfunction temperature
sensor on Peltier Control
Board.
Replace the Peltier Control Board. See
Replacing the Peltier Controller
,
Summary of Contents for DP2K SLP Series
Page 1: ...ENABLING BRIGHT OUTCOMES Service Manual DP2K SLP Series ...
Page 4: ......
Page 10: ...R5906848 04 DP2K SLP Series 10 ...
Page 14: ...R5906848 04 DP2K SLP Series 14 Safety ...
Page 24: ...R5906848 04 DP2K SLP Series 24 General ...
Page 30: ...R5906848 04 DP2K SLP Series 30 Preventative maintenance actions ...
Page 38: ...R5906848 04 DP2K SLP Series 38 Mains Input ...
Page 90: ...R5906848 04 DP2K SLP Series 90 Laser Phosphor Light Source ...
Page 94: ...R5906848 04 DP2K SLP Series 94 10 Reinstall all covers Liquid cooling circuit ...
Page 138: ...R5906848 04 DP2K SLP Series 138 Light Pipe ...
Page 147: ...147 R5906848 04 DP2K SLP Series Optical alignment 12 ...
Page 150: ...R5906848 04 DP2K SLP Series 150 Optical alignment ...
Page 248: ...R5906848 04 DP2K SLP Series 248 Card Cage ...
Page 263: ...263 R5906848 04 DP2K SLP Series Exhaust system 20 ...
Page 265: ...265 R5906848 04 DP2K SLP Series Board Diagnostic LED s 21 ...
Page 270: ...R5906848 04 DP2K SLP Series 270 Board Diagnostic LED s ...
Page 290: ...R5906848 04 DP2K SLP Series 290 Dust Filters ...
Page 294: ...R5906848 04 DP2K SLP Series 294 Troubleshooting ...
Page 382: ...R5906848 04 DP2K SLP Series 382 Troubleshooting ...
Page 394: ...R5906848 04 DP2K SLP Series 394 Projector cleaning ...
Page 395: ...395 Overview Hazards R5906848 04 DP2K SLP Series Appendix A ...
Page 409: ...R5906848 04 DP2K SLP Series 409 ...