12. Lamp House & Lamp replacement
12.8 Resetting the lamp parameters
C
AUTION
:
The “LAMP INFO” parameters MUST be updated after each installation of a xenon lamp inside the
Lamp House. Neglecting this update will result in poor performance and short life time of the xenon lamp.
For a new lamp, how to reset the values
1. While the
Lamp information
window is displayed, click on
Change lamp
(1).
Image 12-36
Reset lamp info, new lamp
A Reset lamp parameters selection window opens (2).
2. To get new lamps, click on
From new list
(3).
The lamp article and serial number opens (4).
3. Fill out the article number of the new lamp (5a)
R5977692 DP2K-S SERIES 10/12/2012
95
Summary of Contents for DP2K-S Series
Page 1: ...DP2K S series User and Installation manual R5977692 00 10 12 2012...
Page 38: ...6 Lenses Lens selection 34 R5977692 DP2K S SERIES 10 12 2012...
Page 60: ...9 Starting up 56 R5977692 DP2K S SERIES 10 12 2012...
Page 80: ...11 Convergence 76 R5977692 DP2K S SERIES 10 12 2012...
Page 104: ...12 Lamp House Lamp replacement 100 R5977692 DP2K S SERIES 10 12 2012...
Page 136: ...15 Removal and installation of the projector covers 132 R5977692 DP2K S SERIES 10 12 2012...