4. Lamp & Lamp House
The software will validate the selected article number (7).
5. Fill out the serial number of the lamp (8).
6. Click
Reset
(9).
Image 4-26
Reset lamp info
C
AUTION
:
For more information about using the Communicator Touch Panel consult the user’s guide of the
Communicator Touch Panel.
4.7
Realignment of the lamp in its re
fl
ector
Each xenon lamp installation requires a realignment of the lamp in its re
fl
ector for optimal performance of the
xenon lamp. Furthermore, it is recommended to realign the lamp after the
fi
rst run time of 100 and 200 hours.
Especially the Z-axis of the lamp.
W
ARNING
:
This procedure may only be performed by quali
fi
ed technical service personnel.
How to realign the lamp in its re
fl
ector?
1. Remove the cover of the lamp compartment to gain access to the X-, Y-, and Z-axis adjustment thumbscrews of the lamp.
2. Switch on the projector and start up the lamp.
3. Go via the Communicator touch panel to the menu
“Installation”
>
“Lamp”
>
“Light output”
.
R5905050 DP2K C-SERIES 10/07/2012
35
Summary of Contents for DP2K-12C
Page 1: ...DP2K C series Installation manual For DP2K 12C DP2K 15C DP2K 20C R5905050 04 10 07 2012...
Page 6: ......
Page 64: ...8 Starting up 58 R5905050 DP2K C SERIES 10 07 2012...
Page 92: ...11 Maintenance 86 R5905050 DP2K C SERIES 10 07 2012...
Page 104: ...13 Specifications 98 R5905050 DP2K C SERIES 10 07 2012...
Page 108: ...A Pin configurations 102 R5905050 DP2K C SERIES 10 07 2012...