DCS-200 • User’s Guide
145
_K==oÉãçíÉ=`çåíêçä
Remote Commands
•
List Format
: Each input type has a different list of valid sample modes.
ISMP -i (input) --list
•
List Response
: 0:"OverSample"
1:"1:1"
fpvk`
•
Description
: Input Sync Type Adjust. This command is only valid for analog
input types.
•
Command Format
: ISYNC -i (input) -s (sync)
•
Parameters
: -i (input): 1 - 8 (7 & 8 only if itype is analog)
-s (sync): 0 - auto, 1 - H/V, 2- CSync, 3- SOG (Default: auto)
•
Query Format
: ISYNC -i (input) -?
•
Query Response
: ISYNC -i (input) -s(sync) --min 0 --max 3
•
List Format
: ISYNC -i (input) --list
•
List Response
: 0:"AUTO"
1:"H/V"
2:"CSYNC"
3:"SOG"
fqvmb
•
Description
: Input Type Adjust. This command is only adjustable for the analog
inputs. Other inputs will provide query information only.
•
Command Format
: ITYPE -i (input) -t (type)
•
Parameters
:
-i (input): 1 - 8 for adjustments (7 & 8 only if itype is analog) ; 1 - 9 for
query
-t (type): 1-analog, 2-Y/C, 3-CVBS, 4-SDI, 5-DVI, 6-YPbPr
•
Query Format
: ITYPE -i (input) -?
•
Query Response
: ITYPE -i (input) -t (type)
•
List Format
: Each input type has a different list of valid input types.
ITYPE -i (input) --list
•
List Response
: 1:"RGB"
2:"Y/C"
3:"CVBS"
4:"SDI"
5:"DVI"
6:"YPbPr"