background image

R9002129

INSTALLATION MANUAL

DATA

708

Summary of Contents for DATA 708

Page 1: ...R9002129 INSTALLATION MANUAL DATA 708 ...

Page 2: ......

Page 3: ...BARCO PROJECTION SYSTEMS Date 260597 Art No R5975987A R9002129 INSTALLATION MANUAL DATA 708 ...

Page 4: ...ion in this manual is subject to change without notice Produced by BARCO NV May 1997 All rights reserved Trademarks are the rights of their respective owners BARCO nv Projection Systems Noordlaan 5 B 8520 Kuurne Belgium Printed in Belgium ...

Page 5: ... 3 1 Where to install the projector 3 2 How to install the projector 3 2 INSTALLATION SET UP 4 1 Access to controls 4 1 Scan adaptation 4 2 PROJECTOR SET UP 5 1 Projector Set Up 5 1 Password mode 5 1 POWER MAINS CONNECTION 6 1 Power mains cord connection 6 1 Fuses 6 2 Switching on off 6 2 INSTALLATION ADJUSTMENTS 7 1 Entering the adjustment mode 7 1 Overview flow chart installation mode 7 2 Instal...

Page 6: ...Table of Contents i 2 5975987A BARCODATA 708 260597 ...

Page 7: ...let contact your electrician to replace your obsolete outlet Do not defeat the purpose of the grounding type plug WARNING FOR THE CUSTOMERS THIS APPARATUS MUST BE GROUNDED EARTHED via the supplied 3 conductor AC power cable If the supplied power cable is not the correct one consult your dealer 1 SAFETY INSTRUCTIONS Notice on Safety This equipment is built in accordance with the requirements of the...

Page 8: ...c If the product has been exposed to rain or water d If the product does not operate normally when the operating instructions are followed Note Adjust only those controls that are covered by the operating instructions since improper adjustment of the other controls may result in damage and will often require extensive work by a qualified technician to restore the product to normal operation e If t...

Page 9: ...on and packing material they will come in handy if you ever have to ship your projector For maximum protection repack your projector as it was originally packed at the factory To open de banding pull on the clip as shown in the first drawing Contents of the shipped box 1 BARCODATA 708 1 remote control 9V battery 1 power cable with outlet plug type ANSI 73 11 1 owner s manual 1 installation manual ...

Page 10: ...Unpacking and Dimensions 2 2 5975987A BARCODATA 708 260597 Projector dimensions mm ...

Page 11: ...ortant As a general rule darken the room to the point where there is just sufficient light to read or write comfortably Spot lighting is desirable for illuminating small areas so that interference with the screen is minimal Which screen type There are two major categories of screens used for projection equipment Those used for front projected images and those for rear projection applications Scree...

Page 12: ... ceiling screen width SW Front view Top view Formulas for Projector to screen distance and correction value A with regard to the screen width for HD145 lenses metric Formulas metric PD m 1 21 x SW m 0 213 A cm 12 95 x SW m 22 83 Formulas for Projector to screen distance and correction value A with regard to the screen width for HD145 lenses inch Formulas inch PD 1 21 x SW 8 39 A 0 1295 x SW 8 99 H...

Page 13: ... Support the top cover with the hand no support is incorporated During some installations it will become handy to remove the top cover totally Therefore pivote the top cover 60 push the top cover to the front side of the projector until it jumps out of its hings Turn the top cover till 90 and lift it up Re install the cover Hook the top cover into the cabinet hinges Pivot the top cover 30 and pull...

Page 14: ...OFFPROJECTORANDUNPLUGTHEPOWERCORD BEFORE CHANGING THE SCAN DIRECTION Gaining access to the scan connectors and the convergence con nectors Open the top cover to remove it see Gaining access to controls To open the chassis loosen both indicated retaining screws Turn the chassis to the front of the projector until it grips in its locks COMM PORT 800 peripherals REMOTE R G S B S VIDEO S VIDEO RS232 O...

Page 15: ...ct connector position Note this check procedure can only be done after power mains connection So first continue with the projector set up and the connections and then return to this checking procedure Switch on the BARCODATA 708 and press ADJUST to start up the adjustment mode Select with the control disk Service and press ENTER The service menu will be displayed Select PROJECTOR SET UP and press ...

Page 16: ...Installation Set Up 4 4 5975987A BARCODATA 708 260597 ...

Page 17: ...VIDEO RS232 OUT RS232 IN strap Password mode With a strap on the controller unit the important projector adjustments can be protected with a password When the password feature is enabled strap mounted on both legs the customer has to enter a password before he can enter the specific adjustment When the password menus are disabled strap mounted only on one leg all adjustments are free This position...

Page 18: ...Projector Set Up 5 2 5975987A BARCODATA 708 260597 ...

Page 19: ...se refer replacement to qualified service personnel Fuse type 2 x T5A 250V Barco order number R314104 Switching on off The projector is switched ON and OFF using the power mains switch ON OFF Pressed ON Not pressed OFF The projector can start now in the operational mode image dis played or in the stand by mode depending on the position of the power up dip switch on the controller unit This DIP swi...

Page 20: ...Power Connection 6 2 5975987A BARCODATA 708 260597 ...

Page 21: ...he adjustment mode ADJUSTMENT MODE Select a path from below Select with or then ENTER EXIT to return GUIDED RANDOM ACCESS INSTALLATION SERVICE IRIS source 1 Random Access Adjustment Guided Adjustment Installation only for qualified technician Service IRIS Press ADJUST to enter the adjustment mode ...

Page 22: ...ed once in red and once in blue CRT PROJECTION ANGLE ADJUSTMENT ENTER to read more EXIT to return CRT PROJECTION ANGLE IS THE FIRST STEP OF STATIC CONVERGENCE ADJUSTMENT IT IS CRITICAL THAT THE RASTERS ARE CENTERED ON THE CRT FACE PLATES PRIOR TO PERFORMING THIS STEP CRT PROJECTION ANGLE ADJUSTMENT ENTER to continue EXIT to return DURING THIS PROCEDURE RED ON GREEN AND THEN BLUE ON GREEN CROSSHAIR...

Page 23: ...returns to the path selection menu When the password mode is active your password will be asked Your password contains 4 digits a Adjusting the projector with the RCU Enter the digits with the numeric keys on the RCU Example 2 3 1 9 For each digit entered a X appears on the screen under the displayed text enter password When your password is correct you get access to the Adjustment mode When the e...

Page 24: ... 126 range 3 min SW 3 20 m 126 max SW 6 00m 236 1 Open the top cover see Gaining access to controls 2 Loosen the lens bolts do not remove them and slide the lens to the front until the scheimflug ring can move freely nutdriver 8 mm or screwdriver See installation instructions before connecting to the supply V NOM 120 230 Volt I MAX 5 2 5 AMP FREQ 60 50 Hz OFF ON Lens bolts Green lens Lens bolts Re...

Page 25: ...ng the wing nut at the rear end of the lens and rotating the lens barrel until the center of the image is clearly focused The corners of the projected image are focused by loosening the wing nut at the front end of the lens and rotating the lens barrel until the corners of the image are clearly focused Repetition of these adjustments may be necessary to optimize optical focusing Press ENTER key to...

Page 26: ...CRT faceplate RASTER CENTERING ENTER to continue EXIT to return CONTRAST LEVEL IS REDUCED AND BRIGHTNESS INCREASED TO MAKE THE RASTER VISIBLE ON THE FACE PLATE OF EACH CRT USE THE ARROW KEYS TO CENTER THE RASTER ON THE GREEN RED AND BLUE CRT RESPECTIVELY forbidden area projected raster crt faceplate border phosphor border correct raster position wrong raster position Press ENTER to activate the ra...

Page 27: ...SW2 SW1 The same projection angle is mis aligned for new screen width SW2 Re alignment is necessary Each screen width change requires readjust ment of the projection angle Projection angle correctly aligned for screen width SW1 CRT PROJECTION ANGLE ADJUSTMENT ENTER to read more EXIT to return CRT PROJECTION ANGLE IS THE FIRST STEP OF STATIC CONVERGENCE ADJUSTMENT IT IS CRITICAL THAT THE RASTERS AR...

Page 28: ...een crosshair Move the red CRT totheoutside away fromthegreenCRT Move the red CRT towards the green CRT ENTER continues to blue and green crosshairs EXIT will return to CRT projection angle adjustment Loosen the four hexagon screws C C Dand D upper and lower fixation latch These screws fasten the cooling house of the blue tube Pivot the blue CRT until the center of the blue image coincides with th...

Page 29: ...nt of the projector Overview of the corrections For detailed information about these corrections and procedures to be followed see owner s manual pages given hereafter are for the random access adjustment mode Shift corrections for the Red Green and Blue image Left Right adjustments Vertical center line bow and skew Left and right keystone adjustment Left and right bow adjustment Horizontal size a...

Page 30: ...Installation Adjustments 7 10 5975987A BARCODATA 708 260597 ...

Page 31: ...mode menu Highlight G2 adjust and press ENTER Select with or then ENTER EXIT to return COMMON SETTINGS G2 ADJUSTMENT CRT RUN IN CYCLE PROJECTOR WARM UP A safety notice will be displayed to warn the operator If you are qualified press ENTER to continue with the G2 adjust ment otherwise press EXIT to return to the service menu SAFETY NOTICE RISK OF ELECTRICAL SHOCK G2 ADJUSTMENT SHOULD BE PERFORMED ...

Page 32: ...st the G2 potentiometers very slowly with a screwdriver until the corresponding LED just stops illuminating Repeat the adjustment for the other colors Once the three G2 potentiometers have been correctly adjusted close the upper electronic chassis and secure with the retaining screws Blue G2 Adjustments Green Red Loosen screws and move the cover plate to the left to access the G2 controls Cover th...

Page 33: ...NAL FIRE PROTECTION ASSOCIATION STD 704M SIGNAL TRESHOLD LIMIT VALUE Units TRESHOLD LIMIT VALUE Units BASE METAL ALLOYS METALLIC COATINGS FILLER METAL PLUS COATING OR CORE FLUX OTHERS MATERIAL SAFETY DATA SHEET Form Approved Bureau Budget No 45 R0338 EMERGENCY PHONE NO TRADE NAME AND SYNONYMS MANUFACTURER S NAME AND FSCM Federal Supply Code for Manufacturer s ADDRESS Number Street City State and Z...

Page 34: ... OR THE RESULTS TO BE OBTAINED FROM THE USE THEREOF VENDOR ASSUMES NO RESPONSABILITY FOR INJURY TO VENDEE OR THIRD PERSONS PROXIMATELY CAUSED BY THE MATERIAL IF REASONABLE SAFETY PROCEDURES ARE NOT ADHERED TO AS STIPULATED IN THE DATA SHEET ADDITIONALLY VENDOR ASSUMES NO RESPONSABILITY FOR INJURY TO VENDEE OR THIRD PERSONS PROXIMATELY CAUSED BY ABNORMAL USE OF THE MATERIAL EVEN REASONABLE SAFETY P...