6. Advanced configuration
Barco – Argus X Terminal – DOC-3265-2 – user's manual – Revision 06 – February-2005
_____________________________________________________________________
6-8
6.1.5
X server parameters
If you want to make changes to the graphical user interface X.11, which are not supported by the configuration
tools introduced in section
, you can manipulate the appearance and the properties of X.11
with a number of options.
On A
RGUS
there are manual pages about the
Xserver
available. For reading these man pages enter
man
Xserver
in the command line:
# man Xserver
Additional options are listed in the table below:
-no_cursor_on_video
The cursor becomes invisible, as long as it is moved over videos.
-ddc_all
DDC detection is asked for every graphic channel. Each graphic channel
needs up to 6 seconds for detection. Therefore this should not be used as a
standard, see section
-no_ddc
DDC detection is not done at all.
-DRGB_888
All RGB sources are digitized and transferred to the O
MNI
S
CALER
with 24 bpp
(RGB 8:8:8) instead of the default setting with 16 bpp (RGB 5:6:5).
Restarting the X server without this option resets the default settings.
-new_video_layout
Configures in a distributed system to each video adapter its own video
channel. For usage of logical video channels please refer to section
Configuring a distributed system
and
6.1.6 Advanced Argus configuration
Table 6-2
The desired options must be entered manually each in a single line in the file:
/etc/MMTconfig/MMTServerConfig
X Server parameters that shall not be changed at a new run of the script
EOSconfig
can be entered between the
two lines:
# BeginSection Private
# EndSection
The file MMTServerConfig contains already lines inserted automatically by the configuration