6.1.2
Do a check on the appliance
1.
Do a check for leaks on the gas pipes and the gas pipe connections. Refer to chapter
2.
Make sure that the pilot light operates correctly. The pilot light must not show any
anomalies.
3.
Make sure that the main burner operates correctly. The fire must not show any
anomalies.
4.
Do a check of the gas supply pressure and the burner pressure.
a) Use the inlet pressure tap and outlet pressure tap on the gas regulator block to
measure the supply pressure and the burner pressure.
b) Measure the pressure when the appliance is off and when the appliance burns
on maximum. Refer to chapter
for the required supply pressure and burner
pressure.
5.
Make sure that the ambient lighting operates correctly.
6.
Do a check on the concentric flue system and the outlet construction. Make sure that
all the connections of the concentric flue system are secure.
6.2
Maintenance procedures
6.2.1
Remove the glass pane Floating Frame (+)
Warning:
Before the start of this procedure make sure the appliance is off
and cooled down to room temperature.
Caution:
Use protective gloves.
Floating Frame / Floating Frame +
1.
Turn off the gas supply to the appliance before removing the glass pane.
2.
With the hook, pull the metal spring
strip on the top, left and right, from
the studs on the door.
Maintenance
Gas Fire Front 70-60
53
Summary of Contents for Gas Fire Front 70-60 PF2
Page 60: ...3 Slide the strip downwards 4 Tighten the nut wings Maintenance 60 Gas Fire Front 70 60...
Page 78: ...9 9 BARBAS Airbox 160 with 4 insert models Dimensions 78 Gas Fire Front 70 60...
Page 79: ...9 10 BARBAS Airbox 320 with 4 insert models Dimensions Gas Fire Front 70 60 79...
Page 82: ...11 EU Declaration of Conformity EU Declaration of Conformity 82 Gas Fire Front 70 60...
Page 83: ...EU Declaration of Conformity Gas Fire Front 70 60 83...
Page 84: ...Your Barbas dealer 002 21 07 2022 352402 248 002...