2.6.3
Overview of the connections on the gas regulator block
C
F
A
E
D
I
G
M
N
B
L
J
K
O
H
A
Pilot light pipe
B
Thermocouple
C
Connector (nut-olive) Ø 4mm
D
Thermocouple interrupter
1
E
Gas supply connection nut Ø 8mm
F
Gas supply connection olive Ø 8mm
G
Connector of gas valve of the rear
burner
H
Gas pipe to rear burner
I
Nut Ø 8mm of the gas valve of the
rear burner
J
Olive Ø 8mm of the gas valve of the
rear burner
K
Control cable of the gas valve of the
rear burner
2
L
Gas valve of the rear burner
M
Olive Ø 8mm
N
Nut Ø 8mm
O
Gas pipe front burner
Figure 6. Connections on the gas regulator block
1
Interrupts the signal of the thermocouple, and bypasses this signal through the receiver.When the
thermocouple signal is cut off by the receiver (requested by the remote control) or when the
thermocouple signal is weak or broken, the gas supply to the pilot light will stop
2
Connects the valve to the receiver
Description
Gas Fire Front 70-60
15
Summary of Contents for Gas Fire Front 70-60 PF2
Page 60: ...3 Slide the strip downwards 4 Tighten the nut wings Maintenance 60 Gas Fire Front 70 60...
Page 78: ...9 9 BARBAS Airbox 160 with 4 insert models Dimensions 78 Gas Fire Front 70 60...
Page 79: ...9 10 BARBAS Airbox 320 with 4 insert models Dimensions Gas Fire Front 70 60 79...
Page 82: ...11 EU Declaration of Conformity EU Declaration of Conformity 82 Gas Fire Front 70 60...
Page 83: ...EU Declaration of Conformity Gas Fire Front 70 60 83...
Page 84: ...Your Barbas dealer 002 21 07 2022 352402 248 002...