6
Maintenance
6.1
Annual maintenance
•
Do all procedures in this section minimum every year.
Caution:
• Use only original parts. Individual parts for replacement or accessories
are available from your Barbas dealer.
• Introduced modifications to the appliance are not permitted.
6.1.1
Clean the appliance
Safety conditions
Caution:
• Turn off the gas supply to the appliance before cleaning.
• Turn off the power supply to the appliance before cleaning.
Procedure
1. Remove the glass. Refer to chapter
2. Remove the content from the burner bed.
3. Clean the removed content carefully with a soft brush.
4. Clean the inside of the appliance, including the main burner, the pilot light burner and
the flue system.
5. Remove the grate.
Figure 39. Position of air intake and primary air inlet openings
6. Clean the combustion air intake
a) Clean the combustion air intake (A) at the bottom sides of the appliance.
b) Clean the primary combustion air inlet openings (B) of the main burners.
7. Clean the ambient light bulbs. Refer to chapter
.
8. Clean the convection air route.
Maintenance
48
Gas Fire Panorama 70-55
Summary of Contents for 70-55 PF2
Page 1: ...Installation and maintenance manual Gas Fire Panorama 70 55 PF2 Serial number Production date...
Page 50: ...2 Remove the side panels and front panel Maintenance 50 Gas Fire Panorama 70 55...
Page 71: ...9 3 Gas Fire Panorama 70 55 PF2 with 4 cm frame Dimensions Gas Fire Panorama 70 55 71...
Page 73: ...9 5 Gas Fire Panorama 70 55 PF2 with 6 cm frame Dimensions Gas Fire Panorama 70 55 73...
Page 75: ...9 7 Gas Fire Panorama 70 55 PF2 with 10 cm frame Dimensions Gas Fire Panorama 70 55 75...
Page 78: ...9 10 Operating unit Dimensions 78 Gas Fire Panorama 70 55...
Page 81: ...11 EU Declaration of Conformity EU Declaration of Conformity Gas Fire Panorama 70 55 81...
Page 82: ...EU Declaration of Conformity 82 Gas Fire Panorama 70 55...
Page 83: ...EU Declaration of Conformity Gas Fire Panorama 70 55 83...