5.2.9
Install the flue gas restriction plate
Safety conditions
Caution:
Install the correct restriction plate as specified in the preparation manual. An
incorrect restriction plate can cause damage to the appliance.
Procedure
1. Remove the glass panes. See chapter
for instructions .
2. Remove the baffle plate ( C), by unscrewing two screws.
3. Install the restriction plate (A) with the fasteners (B) in the appliance. Use the
restriction plate specified in the preparation manual.
4. Install the baffle plate ( C) again with the two screws.
Figure 29. Restriction plate and baffle
5.2.10
Install the mantel iron (option)
The appliance equipped with the 10 cm decorative frame has a mantel iron attached on
the top of the 10 cm frame
5
. The mantel iron supports brickwork or plates above the
appliance.
Make sure the brickwork or plating does not rest on the appliance directly.
1. Remove the 2 protective plates labeled "REMOVE".
5
An appliance with a 4 cm decorative frame does not need a mantel iron.
Installation
40
Gas Fire Panorama 70-55
Summary of Contents for 70-55 PF2
Page 1: ...Installation and maintenance manual Gas Fire Panorama 70 55 PF2 Serial number Production date...
Page 50: ...2 Remove the side panels and front panel Maintenance 50 Gas Fire Panorama 70 55...
Page 71: ...9 3 Gas Fire Panorama 70 55 PF2 with 4 cm frame Dimensions Gas Fire Panorama 70 55 71...
Page 73: ...9 5 Gas Fire Panorama 70 55 PF2 with 6 cm frame Dimensions Gas Fire Panorama 70 55 73...
Page 75: ...9 7 Gas Fire Panorama 70 55 PF2 with 10 cm frame Dimensions Gas Fire Panorama 70 55 75...
Page 78: ...9 10 Operating unit Dimensions 78 Gas Fire Panorama 70 55...
Page 81: ...11 EU Declaration of Conformity EU Declaration of Conformity Gas Fire Panorama 70 55 81...
Page 82: ...EU Declaration of Conformity 82 Gas Fire Panorama 70 55...
Page 83: ...EU Declaration of Conformity Gas Fire Panorama 70 55 83...