Quick Start Guide
Self-Contained, DC-Operated Sensors
For complete technical information about this product, including installation instructions, application requirements and guidelines, EU Declaration of
Conformity, technical specifications, and accessories, see
www.bannerengineering.com
and search 121524.
WARNING: Not To Be Used for Personnel Protection
Never use this device as a sensing device for personnel protection. Doing so could lead to
serious injury or death. This device does not include the self-checking redundant circuitry
necessary to allow its use in personnel safety applications. A sensor failure or malfunction
can cause either an energized or de-energized sensor output condition.
Models
Sensing Mode
Model1
Output
Range
LED
OPPOSED
T306E
-
60 m (196.8 ft)
Infrared, 950 nm
T30SN6R
NPN
T30SP6R
PNP
P
POLAR RETRO
T30SN6LP
NPN
6 m (19.7 ft)
Visible red, 680 nm
T30SP6LP
PNP
FIXED-FIELD
T30SN6FF200
NPN
200 mm (7.9 in) cutoff
Infrared, 880 nm
T30SP6FF200
PNP
T30SN6FF400
NPN
400 mm (15.7 in) cutoff
T30SP6FF400
PNP
T30SN6FF600
NPN
600 mm (23.6 in) cutoff
T30SP6FF600
PNP
Wiring Diagrams
Cabled Emitters
10-30V dc
–
+
1
3
NPN Standard
10-30V dc
–
+
1
3
2
4
Load
Load
PNP Standard
10-30V dc
–
+
1
3
2
4
Load
Load
Key:
Wire 1 = Brown
Wire 2 = White
Wire 3 = Blue
Wire 4 = Black
Quick Disconnect Emitters
1
3
+
−
10–30 V dc
4
2
not used
not used
NPN Alarm
3
1
4
2
10-30V dc
–
+
Alarm
Load
PNP Alarm
3
1
4
2
10-30V dc
–
+
Alarm
Load
1 Integral 2 m (6.5 ft) unterminated cable models are listed.
•
To order the 9 m (30 ft) PVC cable model, add the suffix "W/30" to the cabled model number. For example, T306E W/30.
•
To order the 4-pin M12/Euro-style integral quick disconnect model, add the suffix "Q" to the model number. For example, T306EQ.
•
Models with a quick disconnect require a mating cordset.
T30 Sensors DC-Voltage Series
Original Document
116161 Rev. C
8 October 2018
116161