To use this option, connect all emitter wires in parallel (color-for-color) to the receiver cable via individual wires or the CSB..
splitter cordset (can be used with only emitters and receivers with similar connectors, such as a pair with 8-pin quick
disconnects or a pair with 5-pin quick disconnects.).
Model CSB.. splitter cordsets and DEE2R.. double-ended cordsets allow easy interconnection between an EZ-SCREEN LS
receiver and emitter, providing a single homerun cordset.
Vi
Gn/Ye
Bu
Bk
Wh
Or
Or/Bk
Bn
Scan Code Select
Ground
0V dc
OSSD1
OSSD2
EDM
Fault Output
+24V dc
Figure 33. Individual cordsets
Figure 34. Splitter cordsets
6.5 Wiring Diagrams
6.5.1 Reference Wiring Diagrams
Other interfacing modules and solutions are available, see
Note: For interfacing modules or remotely located safety I/O blocks where pin 5 of a 5-pin M12 QD is not
earth ground, a 4-pin cordset where pin 5 is not physically present or is not electrically connected can be
used (such as MQDEC-406SS double-ended cordset). In such situations, earth ground must be provided
via the mounting brackets.
6.5.2 Generic Wiring Diagram—5-pin and 8-pin Emitter
+24V dc
n.c.*
n.c.*
0V dc
Bn (Pin #1)
Gn/Ye (#5)
Bu (#3)
Bk (#4)
Wh (#2)
Emitter (5-pin Wiring)
5-pin male
M12/Euro-style
(face view)
+24V dc 0V dc
Bn (#1)
Gn/Ye (#7)
Bu (#6)
Bk (#5)
Wh (#4)
Vi (#8)
Or (#3)
Or/Bk (#2)
Emitter (8-pin Wiring)
n.c.*
n.c.*
ID In
Fault Out
8-pin male
M12/Euro-style
(face view)
Scan Code **
Figure 35. Generic Wiring Diagram—Emitter
EZ-SCREEN
®
LS Safety Light Screen
54
www.bannerengineering.com - Tel: +1.763.544.3164