XS/SC26-2xx
XS2so or XS4so
+24Vdc
+24Vdc 0Vdc
0Vdc
SO1a
(SO1 not split)
SO1b
EDM
FSD1
FSD2
1 - Brown
5 - Grey
2 - White
3 - Blue
4 - Black
+24 V dc
+
Do
Q1
Q2
–
PNP OUT *
* Auxillary Output
0V dc
OSSD1
OSSD2
IN1
IN2
SI-RFPT..M
Single-Channel
Safety Stop Circuit
Dual-Channel
Safety Stop Circuit
LOAD
Figure 4. Wiring for a single PNP
3.8.4 Wiring for a Single 8-Conductor Sensor
24
34
14
+24Vdc
+24Vdc
0Vdc
0Vdc
L2/-V
L1/+V
EDM
SC10
23
33
13
Safety Relay Outputs 43/44,
53/54 and 63/64 can be
wired similarly, but require a
separate EDM or AVM input
for monitoring.
MPCE1
MPCE2
Arc Suppressors
Machine
Control
Circuit
Feedback Loop (optional)
5 - Grey
1 - White
6 - Pink
2 - Brown
3 - Green
7 - Blue
8 - Red
4 - Yellow
+24 V dc
+
I1
I2
Q1
–
0V dc
n.c.
n.c.
OSSD1
OSSD2
SI-RFxT-xP8
Q2
IN4
IN3
Figure 5. Wiring for a single 8-conductor sensor
SI-RF Non-Contact RF Safety Switch
12