24
32
14
+24Vdc
+24Vdc
0Vdc
0Vdc
L2/-V
L1/+V
EDM
XS1ro or XS2ro
XS26-2xx
23
31
13
Safety Relay Outputs 43/44,
53/54 and 61/62 can be
wired similarly, but require a
separate EDM or AVM input
for monitoring.
MPCE1
MPCE2
Arc Suppressors
Machine
Control
Circuit
Feedback Loop (optional)
Figure 40. Generic XS/SC26-2 Hookup: Safety Relay Output (Dual-Channel) with EDM
0V dc
S3
S4
Y3
Y1
13
23
33
Y4
Y2
14
24
34
S1
S2
K2
K1
MPCE
2
MPCE
1
IM-T-9A
*
*
+24V dc
Feedback (optional)
* Installation of transient (arc) suppressors across the coils of MPCE1 and MPCE2
is recommended (see Warning)
Machine
Control
XS/SC26-2xx
+24Vdc
0Vdc
SO1a
(SO1 not split)
SO1b
EDM
Figure 41. Generic XS/SC26-2 Hookup: Solid-State Safety Output to IM-T-9A
XS/SC26-2 and SC10-2 Safety Controllers
58