Banner R95C Instruction Manual Download Page 1

B

ANNER

 E

NGINEERING

 C

ORP

.

March 13, 2023

R95C 8-Port 2-Channel Discrete IO-Link Hub Instruction Manual

Features

Models

Overview

The R95C-8B22-KQ hub connects two discrete Input/Output channels to each of the eight unique ports, providing access to monitoring and configuring those ports 

with an IO-Link master. Host mirroring is available where a selected port input/output discrete signal can be routed to Pin 2 (male) on the PLC/Host connection.

Configuration

Figure 1 details the logic flow for each of the eight ports, while the tables define the configuration for each pin.
For more information, see P/N 233583 

R95C-8B22-KQ IO-Link Data Reference Guide

 and P/N 233584 

R95C-8B22-KQ IODD Files

.

Figure 1: 

Logic Flow

Compact bimodal to IO-Link device converter that connects discrete inputs and sends the 

value to the IO-Link Master

Outputs a discrete value as received from IO-Link Master Process Data Out

Enabled Delay Modes: ON/OFF Delay, ON/OFF One-shot, ON/OFF/Retriggerable One-shot, 

ON/OFF Pulse-stretcher and Totalizer

Measurement Metrics: Count, Events Per Minute (EPM), and Duration

Discrete Mirroring: Discrete signals (In/Out) from all eight ports can be mirrored to any of the 

eight ports, Discrete Out, or the host white wire output

Discrete input/output can be independently configured as NPN or PNP

Rugged overmolded design meets IP65, IP67, and IP68

Connects directly to a sensor or anywhere in-line for ease of use

R95C IO-Link hubs are a quick, easy, and economical way to integrate non-IO-Link devices 

into an IO-Link system

C = Converter

8B22 = 8-port, 
bimodal, 2
inputs, 2 outputs  

K = IO-Link

Q = M12 integral 
quick disconnect

Function

Converter

Control

C

Housing

R95

K

Connector

Q

8B22

Input State

Delay Mode

• Disabled
• On/Off Delay
• On/Off/Retriggerable One-shot
• On/Off Pulse Stretcher
• Totalizer

Host

Mirroring

Enable

Host Mirroring

Process Data

Input

Measurement

Statistics

Mirroring

Enabled

Enabled

Input

Disabled

Ouput

Process Data In

Measurement Statistics

Mirroring - Discrete 1 and 2 Output

• Discrete 1 and 2 Input State (active/inactive)

Process Data

Input

Process Data Out

• Discrete 1 and 2 Output State (active/inactive)

• Count
• RPM
• Duration

• Port/Channel selected state driven to Pin 2 (F) and Pin 4 (F)

Process Data

Output

Process Data Out - Discrete 1 and 2 Output

• Process Data Out selected state driven to Pin 2 (F) and Pin 4 (F)

Host Mirroring - Discrete Host Out

• Port/Channel selected state driven to Pin 2 (M)

Discrete 1 & 2

Selection

Mirroring

Enable

Reviews: