5.5.1 Factory Default Settings
Table 4: General Tab Default Settings
Setting
Factory Default
Response Speed
Medium
Signal Strength Threshold
1.0
Target Mode
Nearest Target
Measurement Hold
Disabled
Discrete Output & Remote Input
PNP
Remote Input Wire
Disabled
Push Buttons
Enabled
Table 5: Analog Tab Default Settings
Setting
Factory Default
1515 Models
4545 Models
Range
4 mA to 20 mA (0 V to 10 V)
4 mA to 20 mA (0 V to 10 V)
4mA/0V Point
0.3 m (1 ft)
0.3 m (1 ft)
20mA/10V Point
15.0 m (49.2 ft)
10 m (32.8 ft)
Loss of Signal
3.5 mA (0 V)
3.5 mA (0 V)
Averaging
1× (no averaging)
1× (no averaging)
Table 6: Discrete 1 Tab Default Settings
Setting
Factory Default
1515 Models
4545 Models
Output Mode
Switch Point
Switch Point
Setpoint 1
15.0 m (49.2 ft)
10 m (32.8 ft)
Hysteresis
0.05 m (2 in)
0.05 m (2 in)
NO/NC
Normally Open
Normally Open
On Delay
0 ms
0 ms
Off Delay
500 ms
500 ms
Table 7: Discrete 2 Tab Default Settings
Setting
Factory Default
1515 Models
4545 Models
Output Mode
Switch Point
Switch Point
Setpoint 1
15.0 m (49.2 ft)
10 m (32.8 ft)
Hysteresis
0.05 m (2 in)
0.05 m (2 in)
NO/NC
Normally Open
Normally Open
On Delay
0 ms
0 ms
Off Delay
500 ms
500 ms
R-GAGE
®
T30R Sensor
20
www.bannerengineering.com - Tel: + 1 888 373 6767