Action
Result
Single-pulse the remote input.
T
The green power LED flashes, alternating
with the amber Output LEDs.
Teach Accepted
The sensor flashes the green power LED
three times, then exits remote teach and
returns to run mode.
Teach Not Accepted
The green Power and red Signal Strength
LEDs alternate flashing and the switch point
automatically moves to the maximum range
(the same range as the factory default).
5.2 Remote Setup
Use Remote Setup to set the output mode to either Switch Point Object Teach or Switch Point Background Teach and to
set normally open or normally closed.
Changing the Output 1 Mode using remote input affects both the output configuration (normally open versus normally
closed) and the Teach mode. The output configuration change takes effect immediately and can be used to change the
output between normally open and normally closed without changing the switch point distance. The change in Teach mode
does not immediately change the switch point location, but will affect the behavior of the next remote Teach.
Switch Point Object Teach sets the switch point 0.5 meters (1.6 feet) beyond the location of the target, farther away from
the sensor's face. Use Switch Point Object Teach so that the sensor can reliably detect when a target is in the same
position as when it was configured.
Switch Point Background Teach sets the switch point 1 meter (3.3 feet) in front of the target, closer to the sensor's face.
Use Switch Point Background Teach to reliably ignore the taught background and reliably detect an object that is present in
front of the taught background.
1. Access Remote Setup.
Action
Result
Double-pulse the remote input.
T
T
T
The green power LED flashes slowly.
2. Single pulse the remote input to enter Output 1 mode.
3. Select the desired output mode.
Action
Result
Pulses
Output Mode
1
T
Switch Point Object Teach
(Normally Open)
2
T
T
T
Switch Point Object Teach
(Normally Closed)
3
T
T
T
T
T
Switch Point Background Teach
(Normally Open)
4
T
T
T
T
T
T
T
Switch Point Background Teach
(Normally Closed)
The green Power LED flashes three times,
Normally Open/Normally Closed changes
occur immediately, and the next and any
subsequent remote teach are configured to
be background or object (see
on page 12).
The sensor exits remote teach and returns
to run mode.
R-GAGE
®
Q130RA Sensor
www.bannerengineering.com - Tel: + 1 888 373 6767
13