background image

Diffuse-Mode Laser Sensors

QS30 Series

Printed in USA

09/04

P/N 109027 rev. C

QS30 Laser Features

• Visible laser beam for diffuse sensing

• Available with Class 1 or long-range Class 2 laser

• Excellent optical performance throughout sensing range, even close up

• Easy-to-set Expert-style TEACH options

including Static, Dynamic, and Single-

Point programming plus manual adjustment for fine-tuning

• Easy-to-read operating status indicators, with 8-segment bargraph display  

• Bipolar discrete outputs, PNP and NPN  

• Selectable 30 millisecond OFF-delay 

• Models available with 2 m or 9 m (6.5' or 30') cable or integral quick-disconnect

• Compact housing, mounting versatility – popular 30 mm threaded nose or

side-mount

U.S. Patent #5,808,296

QS30 Laser Models

*9 m (30') cables are available by adding suffix “

W/30

” to the model number of any cabled sensor (e.g., 

QS30LD W/30

).

A model with a QD connector requires a mating cable (see page 10).

Model

Laser
Class

Range

Spot Size at

Focus

Cable*

Output

Type

Excess Gain

QS30LD

Class

1

400 mm

(16")

Approx.

1 mm at
400 mm

(0.039" at

16") 

2 m (6.5') 

5-wire Cable

Bipolar

NPN/PNP

QS30LDQ

Integral

5-pin 

Euro-style

QD

QS30LDL

Class

2

800 mm

(32")

Approx.

1 mm at
800 mm

(0.039" at

32") 

2 m (6.5') 

5-wire Cable

QS30LDLQ

Integral

5-pin 

Euro-style

QD

Beam Pattern

Supply

Voltage

10 -

30V dc

WARNING . . .

Not To Be Used for Personnel Protection

Never use this product as a sensing device for personnel protection. Doing so could lead to serious injury or death.

This product does NOT include the self-checking redundant circuitry necessary to allow its use in personnel safety applications. A

sensor failure or malfunction can cause either an energized or de-energized sensor output condition. Consult your current Banner Safety Products
catalog for safety products which meet OSHA, ANSI and IEC standards for personnel protection.

!

1

10

100

10 mm

.4 in

100 mm

4 in

1000 mm

40 in

1 mm
.04 in

1000

E
X
C
E
S
S

G
A

I

N

DISTANCE

QS30

Diffuse Mode

Laser

400 mm

16.0 in

300 mm

12.0 in

200mm

8.0 in

100 mm

4.0 in

0

0

2 mm

4 mm

6 mm

2 mm

4 mm

6 mm

0

0.08 in

0.16 in

0.24 in

0.08 in

0.16 in

0.24 in

DISTANCE

QS30

Diffuse Mode

1

10

100

10 mm

.4 in

100 mm

4 in

1000 mm

40 in

1 mm
.04 in

1000

E
X
C
E
S
S

G
A

I

N

DISTANCE

QS30

Diffuse Mode

Laser

800 mm

32.0 in

600 mm

24.0 in

400mm

16.0 in

200 mm

8.0 in

0

0

2 mm

4 mm

6 mm

2 mm

4 mm

6 mm

0

0.08 in

0.16 in

0.24 in

0.08 in

0.16 in

0.24 in

DISTANCE

QS30

Diffuse Mode

Summary of Contents for QS30 Series

Page 1: ...ntegral 5 pin Euro style QD QS30LDL Class 2 800 mm 32 Approx 1 mm at 800 mm 0 039 at 32 2 m 6 5 5 wire Cable QS30LDLQ Integral 5 pin Euro style QD Beam Pattern Supply Voltage 10 30V dc WARNING Not To Be Used for Personnel Protection Never use this product as a sensing device for personnel protection Doing so could lead to serious injury or death This product does NOT include the self checking redu...

Page 2: ...reverse polarity over voltage and transient voltages Output Response Time 500 microseconds Indicators 8 segment red bargraph Signal strength relative to switch point Green LED Power ON Yellow LED Output conducting Construction ABS plastic housing acrylic lens cover Connections Environmental Rating IP67 NEMA 6 Delay at Power Up 1 second max outputs do not conduct during this time Output Protection ...

Page 3: ... beam paths either above or below eye level where practical CAUTION Use of controls or adjustments or performance of procedures other than those specified herein may result in hazardous radiation exposure per EN 60825 Do NOT attempt to disassemble this sensor for repair A defective unit must be returned to the manufacturer Class 1 Lasers that are safe under reasonably foreseeable conditions of ope...

Page 4: ...ntered on a single taught condition Single Point TEACH programming may be accomplished only statically Remote Programming The Remote Programming function may be used to program the sensor remotely or to disable the push buttons for security Connect the gray wire of the sensor to ground 0V dc with a remote programming switch connected between them Pulse the remote line according to the diagrams in ...

Page 5: ...nt TEACH and Manual Adjust Using Manual Adjust with Two Point TEACH moves the switching threshold The lighted LED on the light bar will move to exhibit the relative amount of received signal Push Button Remote Line Display Shows Press and Hold No action required sensor is ready for 1st TEACH condition Power LED OFF Output LED ON Bargraph 5 6 Flashing Present Output ON condition Click Present Outpu...

Page 6: ...e tuned whenever the sensor is in RUN mode by clicking the and buttons However when a manual adjustment is made the adaptive threshold system is disabled cancelled Push Button Remote Line Display Shows Press and Hold Hold remote line low to ground Power LED OFF Bargraph 7 8 flashing Present Output ON and OFF conditions Continue to hold Present Output ON and OFF conditions Continue to hold remote l...

Page 7: ...anging Light Dark Operate status in SETUP mode Single Point TEACH programming may be accomplished only using Static TEACH The sensor learns a single sensing condition and adds switching thresholds above and below the taught condition to create a sensing window Single Point TEACH and Manual Adjust Using Manual Adjust with Single Point TEACH expands or contracts the size of the window The lighted LE...

Page 8: ...icating return to RUN mode NOTES If SETUP mode programming is interrupted and remains inactive for 60 seconds the sensor returns to RUN mode with the most recent settings i e exits and saves current selection SETUP mode operates in the background while the outputs are active Manual Adjust Use during RUN mode accomplished via push buttons only Two Point TEACH Static or Dynamic Fine tunes sensing th...

Page 9: ...s with 21 CFR 1040 10 and 1040 11 except for deviations pursuant to Laser Notice No 50 dated 7 26 01 32 5 mm 1 28 35 0 mm 1 38 QS30LD QS30LD 10 30 VDC 10 30 VDC 2 x ø3 3 mm 0 125 max torque 0 7 Nm 6 in lbs M30 x 1 5 Thread max torque 6 Nm 53 in lbs with included 30 mm mounting nut Dimensions QD Models Cabled Models Hookups Cabled Models QD Models bn Remote Teach bu wh bk gy 10 30V dc Load Load 150...

Page 10: ...isconnect Cables 38 mm max 1 5 M12 x 1 ø 15 mm 0 6 38 mm max 1 5 Style Model Length Dimensions 5 pin Euro style straight MQDC1 506 MQDC1 515 MQDC1 530 2 m 6 5 5 m 15 9 m 30 M12 x 1 ø 15 mm 0 6 44 mm max 1 7 White Wire Blue Wire Black Wire Brown Wire Gray Wire Pin out 5 pin Euro style right angle MQDC1 506RA MQDC1 515RA MQDC1 530RA 2 m 6 5 5 m 15 9 m 30 ...

Page 11: ... bracket for cable models Clearance for M4 8 hardware 12 tilt adjustment Heavy duty die cast bracket M18 vertical mounting option 8 tilt adjustment with cabled units Nuts and lockwasher included SMBQS30LT 14 gauge stainless steel for QD models with right angle cables Tall right angle mounting bracket 8 Tilt adjustment 64 4mm 2 54 1 9mm 0 07 4 5mm 0 18 24 0mm 0 95 11 0mm 0 43 ø4 3mm ø0 17 44 0mm 1 ...

Page 12: ...ound to be defective at the time it is returned to the factory during the warranty period This warranty does not cover damage or liability for the improper application of Banner products This warranty is in lieu of any other warranty either expressed or implied P N 109027 rev C Banner Engineering Corp 9714 Tenth Ave No Minneapolis MN USA 55441 Phone 763 544 3164 www bannerengineering com Email sen...

Reviews: