background image

WORLD-BEAM QS18 Expert with IO-Link

Instruction Manual

Original Instructions
196872 Rev. B
19 September 2019

©

 Banner Engineering Corp. All rights reserved

196872

Summary of Contents for QS18EK6CV45Q8

Page 1: ...WORLD BEAM QS18 Expert with IO Link Instruction Manual Original Instructions 196872 Rev B 19 September 2019 Banner Engineering Corp All rights reserved 196872 ...

Page 2: ...12 4 Select TEACH SET Method 14 5 Configure TEACH SET 15 6 TEACH SET 17 7 Specifications 19 7 1 Self Contained Models Specifications 19 7 2 Opposed Mode Models Specifications 20 7 3 Dimensions 21 7 4 Self Contained Models Performance Curves 22 7 5 Opposed Mode Models Performance Curves 25 8 Accessories 26 8 1 Cordsets 26 8 2 Brackets 27 8 3 Retroreflectors 28 9 Contact Us 29 10 Banner Engineering ...

Page 3: ... very dark objects Health data available over IO Link Auto compensation algorithm provides long and reliable operation by compensating for dust build up and ambient temperature changes Fast response speed for high speed applications User selectable threshold offset percentage to optimize performance for the type of object being detected Easy configuration of the sensor by IO Link remote input or p...

Page 4: ...ti function input output QS18EK6EQ8 Infrared 940 nm OPPOSED IO Link and multi function input QS18EK6RQ8 IO Link push pull output and multi function input output 4 Pin M12 Euro style integral quick disconnect models listed To order the 150 mm 6 in PVC cable model with a 4 pin M12 Euro style quick disconnect replace the suffix Q8 with Q5 in the model number For example QS18EK6LPQ5 To order the 4 in ...

Page 5: ...wer Flashing ON OFF Notification Push button has been locked out Flashes four times and returns to solid On after button press ON OFF Opposed Mode Emitter Indicators Sensor Condition Green LED Amber LED Power On ON OFF Notification Push button has been locked out Flashes four times and returns to solid On after button press OFF 1 3 Opposed Mode Models Noise and Crosstalk Immunity Optical synchroni...

Page 6: ...put Factory Default 4 1 3 2 10 30V dc CH1 CH2 PUSH PULL Load Load Figure 1 Channel 1 IO Link Channel 2 PNP Output IO Link with PNP Remote Input 4 1 3 2 10 30V dc CH1 CH2 PUSH PULL Load Remote Input Figure 2 Channel 1 IO Link Channel 2 PNP Remote Input Key 1 Brown 2 White 3 Blue 4 Black3 Note NPN PNP and Remote Input configurations are programmable using IO Link Note Enable the remote input wire fu...

Page 7: ...t PNP Output and Remote Input 4 1 3 2 10 30V dc CH1 CH2 Load Remote Input Figure 6 Channel 1 PNP Output Channel 2 PNP Remote Input 1 4 3 2 Figure 7 Sensor Pinout M12 Euro style Models Male 3 2 1 4 Figure 8 Sensor Pinout M8 Pico Style Models Male WORLD BEAM QS18 Expert with IO Link www bannerengineering com Tel 1 888 373 6767 7 ...

Page 8: ...ocedures and is enabled upon return to Run mode See the Input Flowcharts for configuration information Self contained models Figure 9 p 9 Opposed mode emitters Figure 10 p 10 Opposed mode receivers Figure 11 p 11 Following any TEACH or SET procedure other than Two Point Static TEACH the Output ON condition Light or Dark Operate setting remains as it was last configured To change that setting or th...

Page 9: ...ory defaults flashing both Green and Amber LEDs 8X followed by acceptance flash 8x Push Button or Remote Input Wire Configuration using remote input wire when enabled through IO Link 1x Second Pulse Completes Teach 2 Point Static and Dynamic Teach only Configure output to Light Operate flashing Green and Amber 1X followed by acceptance flash Configure output to Dark Operate flashing Green and Ambe...

Page 10: ...MITTER Remote Input Wire Configuration using remote input wire when enabled through IO Link High Speed flashing of both Green and Amber LEDs 1X followed by acceptance flash Configure to A Frequency flashing of both Green and Amber LEDs 2X followed by acceptance flash Configure to B Frequency flashing of both Green and Amber LEDs 3X followed by acceptance flash Configure to C Frequency flashing of ...

Page 11: ... Amber LEDs 5X followed by acceptance flash Select Two Point Static TEACH flashing of both Green and Amber LEDs 1X followed by acceptance flash Select Dynamic TEACH flashing of both Green and Amber LEDs 2X followed by acceptance flash Select Window SET flashing of both Green and Amber LEDs 3X followed by acceptance flash Select TEACH SET Method flashing Amber LED at 1Hz Select Light SET flashing o...

Page 12: ...k Device AOIs as desired linking them to the Master AOI as shown in the relevant AOI documentation Banner has also developed Function Blocks to simplify ease of use between the QS18E multiple third party vendors IO Link masters and the Siemens TIA Portal software package for Siemens PLCs Two types of Function Blocks files for TIA Portal are listed below The files and more information can be found ...

Page 13: ...ash Remote From Run mode pulse the remote three time then pulse two times to disable the button Push Button Enable Push Button From Run mode click the button three times then click one time to enable the button Green and amber LEDs flash once in union followed by acceptance flash Remote From Run mode pulse the remote three time then pulse one time to enable the button Remote Input Wire Disable Ena...

Page 14: ... Click the button one time The selected TEACH SET method is enabled Dynamic TEACH Click the button two times Window SET Click the button three times Light SET Click the button four times Dark SET Click the button five times Opposed Mode Models Opaque Mode Click the button six times IO Link Two Point Static TEACH Set BDC1 Mode using IO Link Dynamic TEACH Window SET Light SET Dark SET Opposed Mode M...

Page 15: ... the ON and OFF conditions 3 Click the Push Button once to stop the Dynamic TEACH process and return to Run mode Window SET 1 Present the target condition 2 Press and hold the button for greater than 2 seconds to configure the target condition and return to Run mode Light SET Dark SET Opposed Mode Models Opaque Mode IO Link Action Result Two Point Static TEACH 1 Present the output ON target condit...

Page 16: ...LED indicators flash six times rapidly in unison acceptance flash 3 The sensor returns to Run mode with valid thresholds Invalid Teach Condition 1 The green and amber indicator LEDs flash two times in unison 2 The green and amber LED Indicators flash six times rapidly in unison acceptance flash 3 The sensor returns to Run Mode with coerced thresholds Dynamic TEACH 1 Pulse the remote line once to s...

Page 17: ...ned Models Output ON and OFF conditions may be reversed by switching the TEACH order or by changing the Light Dark Operate setting Dynamic TEACH is recommended for applications where a machine or process may not be stopped for configuration Darkest no signal Most Light saturated signal Output OFF Output ON 2nd Taught Condition 1st Taught Condition Sensor positions threshold between presented condi...

Page 18: ... Self contained models 30 default Opposed mode models 50 default Any condition lighter than the threshold causes the output to change state In Light Operate mode the presented condition is the Output OFF condition In Dark Operate mode the presented condition is the Output ON condition Reverse the Output ON and OFF conditions by changing the Light Dark Operate setting Dark SET is recommended for ap...

Page 19: ... and FP Models Two point Static TEACH LP Models Light SET Output Logic D DV CV and FP Models Light Operate LP Models Dark Operate Output Response Time Standard Offset Percentage 30 Push Button Unlocked Auto Compensation Enabled OFF Delay Disabled Pin 4 Output IO Link Enabled Detection Output Push pull Pin 2 Output Detection Output High speed output when using IO Link on Pin 4 Required Overcurrent ...

Page 20: ... High Speed Auto 350 212 A B C Fixed 1000 400 A B C Auto 1100 600 Emitter Power High Power is Power 5 Low Power is Power 0 The following power levels are available via IO Link to set intermediate power levels when looking for good contrast control with separation distances 4 m Power 5 Power 4 Power 3 Power 2 Power 1 and Power 0 Emitter LED EV model Visible red 625 nm E models Infrared 940 nm Indic...

Page 21: ...urrent Protection Amps 20 5 0 22 3 0 24 2 0 26 1 0 28 0 8 30 0 5 Construction Housing ABS Window PMMA Mounting Torque Nose Mount 18 mm mounting nut 20 Ibf in 2 3 N m Side Mount Two M3 screws 5 Ibf in 0 6 N m Vibration and Mechanical Shock All models meet MIL STD 202G Method 201A requirements Also meets IEC 60947 5 2 Connections PVC jacketed 4 conductor 2 m 6 5 ft or 9 m 30 ft unterminated cable or...

Page 22: ...lf Contained Models Performance Curves Performance using Dark SET performed in no light condition Polarized Retroreflective Excess Gain Beam Pattern Diffuse Based on use of 90 reflectance white test card Excess Gain Beam Pattern WORLD BEAM QS18 Expert with IO Link 22 www bannerengineering com Tel 1 888 373 6767 ...

Page 23: ...Diffuse Based on use of 90 reflectance white test card Excess Gain Beam Pattern Convergent Excess Gain Beam Pattern WORLD BEAM QS18 Expert with IO Link www bannerengineering com Tel 1 888 373 6767 23 ...

Page 24: ...Convergent Excess Gain Beam Pattern Fiber Optic Plastic Excess Gain Beam Pattern WORLD BEAM QS18 Expert with IO Link 24 www bannerengineering com Tel 1 888 373 6767 ...

Page 25: ...6 20 24 1000 800 600 400 200 0 200 400 600 800 1000 High Power Mode Low Power Mode Infrared QS18EK6E QS18EK6R Excess Gain Curve Beam Pattern 1 10 100 1000 10000 DISTANCE mm EXCESS GAIN 0 1 1 10 100 High Power Mode Low Power Mode Power High Power Mode Distance mm Width mm 0 4 8 12 16 20 24 1000 800 600 400 200 0 200 400 600 800 1000 High Power Mode Low Power Mode WORLD BEAM QS18 Expert with IO Link...

Page 26: ... Typ 1 26 30 Typ 1 18 ø 14 5 0 57 M12 x 1 MQDC 415RA 4 57 m 15 ft MQDC 430RA 9 14 m 30 ft MQDC 450RA 15 2 m 50 ft 4 Pin Threaded M8 Pico Style Cordsets Single Ended Model Length Style Dimensions Pinout Female PKG4M 2 2 m 6 56 ft Straight ø 9 5 35 Typ M8 x 1 4 3 1 2 1 Brown 2 White 3 Blue 4 Black PKG4M 5 5 m 16 4 ft PKG4M 9 9 m 29 5 ft PKW4M 2 2 m 6 56 ft Right Angle ø 9 5 28 Typ 20 Typ M8 x 1 PKW4...

Page 27: ...djustment Easy sensor mounting to extruded rail T slots Metric and inch size bolts available Side mounting of some sensors with the 3 mm screws included with the sensor 40 43 A B B 7 M3 0 5 Model Bolt Thread A SMBQ4XFA 3 8 16 2 in SMBQ4XFAM10 M10 1 5 50 SMBQ4XFAM12 n a no bolt included Mounts directly to 12 mm in rods SMB18AFA Protective swivel bracket with tilt and pan movement for precision adju...

Page 28: ...ature 20 C to 60 C 4 F to 140 F Optional brackets are available Approximate size 92 mm 92 mm BRT 40X19A Rectangular acrylic target Reflectivity Factor 1 3 Temperature 20 C to 60 C 4 F to 140 F Approximate size 19 mm 60 mm overall 19 mm 40 mm reflector BRT 84 Round acrylic target Reflectivity Factor 1 4 Temperature 20 C to 60 C 4 F to 140 F Optional brackets are available Size 84 mm diameter Mounti...

Page 29: ... is located at 9714 Tenth Avenue North Minneapolis MN 55441 USA Phone 1 888 373 6767 For worldwide locations and local representatives visit www bannerengineering com WORLD BEAM QS18 Expert with IO Link www bannerengineering com Tel 1 888 373 6767 29 ...

Page 30: ...UENTIAL OR SPECIAL DAMAGES RESULTING FROM ANY PRODUCT DEFECT OR FROM THE USE OR INABILITY TO USE THE PRODUCT WHETHER ARISING IN CONTRACT OR WARRANTY STATUTE TORT STRICT LIABILITY NEGLIGENCE OR OTHERWISE Banner Engineering Corp reserves the right to change modify or improve the design of the product without assuming any obligations or liabilities relating to any product previously manufactured by B...