Q5Z Global Laser Measurement Sensor With IO-Link Instruction Manual
25
Chapter Contents
IO-Link is a point-to-point communication link between a master device and sensor. Use IO-Link to parameterize sensors and
transmit process data automatically.
For the latest IOLink protocol and specifications, see
.
Each IOLink device has an IODD (IO Device Description) file that contains information about the manufacturer, article num
ber, functionality etc. This information can be easily read and processed by the user. Each device can be unambiguously
identified via the IODD as well as via an internal device ID. Download the
Q5Z Global
's IOLink IODD package (p/n
206833)
from Banner Engineering's website at
Banner has also developed Add On Instruction (AOI) files to simplify easeofuse between the
Q5Z Global
, multiple thirdpar
ty vendors' IO-Link masters, and the Logix Designer software package for Rockwell Automation PLCs. Three types of AOI
files for Rockwell Allen-Bradley PLCs are listed below. These files and more information can be found
.
Process Data AOIs
—These files can be used alone, without the need for any other IOLink AOIs. The job of a Process Data
AOI is to intelligently parse out the Process Data word(s) in separate pieces of information. All that is required to make use of
this AOI is an EtherNet/IP connection to the IO-Link Master and knowledge of where the Process Data registers are located
for each port.
Parameter Data AOIs
—These files require the use of an associated IOLink Master AOI. The job of a Parameter Data AOI,
when working in conjunction with the IOLink Master AOI, is to provide quasirealtime read/write access to all IOLink para
meter data in the sensor. Each Parameter Data AOI is specific to a given sensor or device.
IO-Link Master AOIs
—These files require the use of one or more associated Parameter Data AOIs. The job of an IOLink
Master AOI is to translate the desired IOLink read/write requests, made by the Parameter Data AOI, into the format a specif
ic IOLink Master requires. Each IOLink Master AOI is customized for a given brand of IOLink Master.
Add and configure the relevant Banner IO-Link Master AOI in your ladder logic program first; then add and configure Banner
IOLink Device AOIs as desired, linking them to the Master AOI as shown in the relevant AOI documentation.
IO-Link Interface
Chapter 7