June 22, 2023
LTF Time Of Flight Laser Distance Sensor Instruction Manual
22
Remote Input:
Not available
Default:
50 mm
Adjust 20 mA (10 V)
The Adj20mA (Adj10V) option manually adjusts the distance at which the Analog Output is 20 mA (10 V). The value is ad-
justable between the sensor's range. It is required to at least maintain the minimum window size.
Navigate:
MENU
›
A_OUT
›
Adj20mA (Adj10V)
Remote Input: Not available
Default:
12000 mm for LTF12, 24000 mm for LTF24
Slope
The Slope option sets the slope as positive or negative. This swaps the 4 mA and 20 mA (0 V and 10 V) values.
Navigate:
MENU
›
A_OUT
›
Slope
Remote Input
: Available
Default
: Positive
Slope—Current-Sourcing Models
4
Near
Window
Far
Window
20
Target Position
Analog Output (mA)
Positive
Slope
The analog current output tracks slightly beyond each window limit
(from 3.8 mA to 20.2 mA)
Slope—Voltage-Sourcing Models
0
Near
Window
Far
Window
10
Analog Output (V dc)
Positive
Slope
Target Position
The analog voltage output tracks slightly beyond the upper window
limit (up to 10.2 V)
Access the slope setting.
Method
Action
Result
Push Button
Navigate:
MENU
›
A_OUT
›
Slope
"Slope
" and the current setting dis-
play.
Remote Input
a. Double-pulse the remote input to enter set-
up mode.
b. Single-pulse the remote input to ac-
cess
A_OUT Slope
.
T
T
T
T
a. "
REMOTE SETUP" displays.
b. "Slope
" and the current setting dis-
play.
1.
Set the slope.
2.
© Banner Engineering Corp.
Summary of Contents for LTF
Page 4: ...Blank page 4...
Page 12: ...Blank page 12...
Page 44: ...Blank page 44...
Page 52: ...Blank page 52...
Page 58: ...Blank page 58...
Page 60: ...LinkedIn Twitter Facebook 2023 All rights reserved www bannerengineering com...