3.6 Input Menu (INPUT)
Use this menu to view or change the:
•
Multi-function input type
•
Active state of the remote
input
MENU INPUT
or
or
Go Back to Parent Menu
Select Menu Item
Press to Save Setting
Press and Hold to Go Back
to Run Mode
INPUT Active
INPUT Type
Active High
Active Low
Type LasrEnbl
Type Teach
Type SyncMstr
Type SyncSlve
Type Disabled
Figure 18. Input Menu Map
3.6.1 Input Type
The Type option sets the input type.
Navigate: MENU > INPUT > Type
Remote Input: Not available
Default: Teach
Input Type
Description
Teach
The remote input is used to TEACH and program the sensor. (Default)
LasrEnbl
The remote input is used to control when the laser emitter is On/Off.
SyncMstr
The remote input is used as the Master Sync output to an attached Slave sensor (see
on page 27).
SyncSlve
The remote input is used as the Slave Sync input from an attached Master sensor (see
on page 27).
Disabled
The remote input is disabled.
3.6.2 Input Active
The Active option sets the active state of the remote input. Use the Active options to change the active input to Low or
High.
Navigate: MENU > INPUT > Active
Remote Input: Not available
Default: Low
Input Active
Description
Low
The remote input detects low (0 V) inputs and high-to-low transitions. (Default)
High
The remote input detects high (V+) inputs and low-to-high transitions.
L-GAGE
®