June 22, 2023
LTF Time Of Flight Laser Distance Sensor With IO-Link Instruction Manual
16
Remote TEACH window sizes
Variable
Remote TEACH Window Size (mm)
LTF12
LTF24
X1
10
10
X2
20
20
X3
100
100
X4
500
500
X5
2000
2000
X6
11950
23950
Locking and Unlocking the Sensor
Use the lock and unlock feature to prevent unauthorized or accidental programming changes. A lock symbol displays in the
upper left corner of the display to indicate when the sensor is locked. When locked, the menus are available to view settings,
but the values cannot be changed. The remote input is also disabled, except for the unlock function.
Button Instructions
--To lock or unlock the sensor using the buttons, press and hold
Down
and
Escape
simultaneously for 3
seconds.
Remote Input Instructions
Access the setup mode.
Action
Result
Double-pulse the remote input.
T
T
T
"REMOTE SETUP
" displays.
1.
Access the lock/unlock function.
Action
Result
Four-pulse the remote input.
T
T
T
T
T
T
T
"LOCK" and the current status (unlocked or
locked) display.
2.
Lock or unlock the sensor.
Action
Result
Unlock :
Single-pulse the remote line.
T
"Unlocked" flashes and the sensor returns to
Run mode. The sensor is unlocked.
Lock:
Double-pulse the remote input.
T
T
T
"Locked" flashes and the sensor returns to
Run mode. The sensor is locked and the
lock symbol displays in the upper left cor-
ner.
3.
© Banner Engineering Corp.