11.9 Firmware Update
Main Menu > System > Firmware Update
Use the Firmware Update screen to load the latest device firmware. The Firmware Update screen lists the firmware versions
it finds in the
BANNER\FIRMWARE
folder on the USB flash drive. When you receive a firmware update from Banner
Engineering, be sure to put it in the
BANNER\FIRMWARE
folder on the USB flash drive.
Note: The Firmware Update menu is not available in the Emulator.
11.10 iVu Trigger, Remote Teach, and I/O Waveforms
The iVu has two input signals—Trigger and Remote Teach. The default setting is to detect the low to high transition. To
change this setting, go to Main Menu > System > Discrete I/O > Input Polarity on the iVu.
11.10.1 PNP (Low-to-High) Trigger and Remote Teach Input
Waveforms
Power up
Trigger
Remote
Teach
Pink
Wire Color
Function
Gray
The iVu triggers from low to high, and Remote Teach behaves electrically like trigger.
Note:
Table 15: Required iVu Input Signal Voltage
ON
OFF
PNP
+10 V dc to 30 V dc
< 2 V dc
11.10.2 NPN (High-to-Low) Trigger and Remote Teach Input
Waveforms
Trigger
Remote
Teach
Pink
Wire Color
Function
Gray
Power up
The iVu triggers from high to low, and Remote Teach behaves electrically like trigger.
iVu Plus TG and Color Gen2 Image Sensors
www.bannerengineering.com - Tel: + 1 888 373 6767
73