• When a client closes the connection, a log entry indicates that the channel is no longer being listened to
13.3.2 Ethernet I/O
Ethernet I/O Status
Use the Ethernet I/O Status screen to verify that the Ethernet wiring was correctly set up. In addition to determining if the
link has been established, incoming and outgoing traffic can be monitored.
Figure 82. Ethernet I/O Status Screen
13.3.3 Serial I/O
Using the Port Status Screen for Testing RS-232 Communications
Use Port Status screen to ensure data is entering and exiting the iVu BCR. This can be useful for debugging issues such as
improper wiring, mismatched baud rates, or other serial I/O issues. To access the Port Status screen, go to Main Menu >
System > Communications > Serial I/O and click Status.
• The upper field shows the bytes received (request frame) on the iVu BCR from the control device
• The lower field shows the bytes sent (response frame) from the iVu BCR to the control device
Figure 83. Port Status Screen
Port Errors
The Port Errors screen can help to debug communications channel issues: Parity, Break, and Framing indicate mismatched
port settings or, in the case of Break, incorrect cabling.
Using the
iVu BCR
Command Channel Sample Application or a Terminal
Program for Testing
The easiest way to test that the iVu command channel is correctly receiving and transmitting data is to use either the iVu
BCR Command Channel Sample App (available in the iVu BCR installation package) or to use a terminal program running
on a PC.
If you are using a terminal program, in the terminal program's configuration:
• Set new-line transmit to <CR><LF> (and set the end-of-frame delimiters on the iVu BCR to match)
• Enable local echo