Adding sensor-specific output information, including data from decoded barcode symbols, requires the use of a
BCR sensor output submodule, plugged into Slot 2 Subslot 1. The iiVu BCR provides different options for
configuring this submodule, based on the space required by the decoded barcode data. The selection of sensor
output submodules is based on size, allowing the user to control network bandwidth use.
Another optional addition to the configuration is called the Compare String Submodule, plugged into Slot 3 Subslot
1. This submodule allows the controller (PLC) to send new ASCII compare strings or string masks to the iVu BCR.
The selection of compare string submodules is based on the desired length of the compare string data used.
The iVu BCR Command Channel Module can be plugged into Slot 4. The selection of Command Channel
Submodules is based on the required length of the data output string.
Follow Step 5 and Step 6 to add a submodule to the configuration (optional).
5. Click S2 to go to the configuration window and add a submodule.
Figure 123. PROFINET Module Map Screen—Add Submodule
6. Click the Drop-Down Arrow next to Disabled to open the list of submodule slots.
7. Select a submodule and hit enter.
The submodule slot now shows an icon, which means that it has been configured.
8. Set up all submodules for your application.
Figure 124. PROFINET Module Map Screen—With a Submodule Added
The iVu BCR PROFINET configuration is complete. The PLC can now be configured to complete the PROFINET
connection.
Description of Modules
Table 26: Assignment of Slots and Subslots
Slot 1 - BCR Control and Status
Module
Slot 2 - BCR Sensor Output
Module
Slot 3 - BCR Control Module Slot 4 - Command Channel
Module
Subslot 1
BCR Inspection Result Submodule
sensor output submodules
Compare String Submodule
Command Channel
Command submodules
Subslot 2
BCR Device Control Submodule
—
—
Command Channel
Response submodules
iVu Plus BCR Gen2 Series Sensor